CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

The Utility of Rapid Atrial Pacing Immediately Post-TAVR to Predict the Need for Pacemaker Implantation Long-term effects of intensive glucose lowering on cardiovascular outcomes Transcatheter Aortic Valve Replacement vs Surgical Replacement in Patients With Pure Aortic Insufficiency The conductive function of biopolymer corrects myocardial scar conduction blockage and resynchronizes contraction to prevent heart failure The Role of the Pericardium in Heart Failure: Implications for Pathophysiology and Treatment Three vs twelve months of dual antiplatelet therapy after zotarolimus-eluting stents: the OPTIMIZE randomized trial Incidence, predictors, and outcomes associated with acute kidney injury in patients undergoing transcatheter aortic valve replacement: from the BRAVO-3 randomized trial Percutaneous Left Atrial Appendage Closure for Stroke Prophylaxis in Patients With Atrial Fibrillation: 2.3-Year Follow-up of the PROTECT AF (Watchman Left Atrial Appendage System for Embolic Protection in Patients With Atrial Fibrillation) Trial Use of IVUS guided coronary stenting with drug eluting stent: a systematic review and meta-analysis of randomized controlled clinical trials and high quality observational studies Coronary plaque redistribution after stent implantation is determined by lipid composition: A NIRS-IVUS analysis

Original ResearchVolume 74, Issue 7, August 2019

JOURNAL:J Am Coll Cardiol. Article Link

Predicting Major Adverse Events in Patients With Acute Myocardial Infarction

T Nestelberger, J Boeddinghaus, the APACE Investigators et al. Keywords: acute myocardial infarction; clinical assessment; electrocardiography; high-sensitivity cardiac troponin; major adverse cardiac events

ABSTRACT


BACKGROUND- Early and accurate detection of short-term major adverse cardiac events (MACE) in patients with suspected acute myocardial infarction (AMI) is an unmet clinical need.

 

OBJECTIVES - The goal of this study was to test the hypothesis that adding clinical judgment and electrocardiogram findings to the European Society of Cardiology (ESC) high-sensitivity cardiac troponin (hs-cTn) measurement at presentation and after 1 h (ESC hs-cTn 0/1 h algorithm) would further improve its performance to predict MACE.

 

METHODS- Patients presenting to an emergency department with suspected AMI were enrolled in a prospective, multicenter diagnostic study. The primary endpoint was MACE, including all-cause death, cardiac arrest, AMI, cardiogenic shock, sustained ventricular arrhythmia, and high-grade atrioventricular block within 30 days including index events. The secondary endpoint was MACE + unstable angina (UA) receiving early (≤24 h) revascularization.

 

RESULTS- Among 3,123 patients, the ESC hs-cTnT 0/1 h algorithm triaged significantly more patients toward rule-out compared with the extended algorithm (60%; 95% CI: 59% to 62% vs. 45%; 95% CI: 43% to 46%; p < 0.001), while maintaining similar 30-day MACE rates (0.6%; 95% CI: 0.3% to 1.1% vs. 0.4%; 95% CI: 0.1% to 0.9%; p = 0.429), resulting in a similar negative predictive value (99.4%; 95% CI: 98.9% to 99.6% vs. 99.6%; 95% CI: 99.2% to 99.8%; p = 0.097). The ESC hs-cTnT 0/1 h algorithm ruled-in fewer patients (16%; 95% CI: 14.9% to 17.5% vs. 26%; 95% CI: 24.2% to 27.2%; p < 0.001) compared with the extended algorithm, albeit with a higher positive predictive value (76.6%; 95% CI: 72.8% to 80.1% vs. 59%; 95% CI: 55.5% to 62.3%; p < 0.001). For 30-day MACE + UA, the ESC hs-cTnT 0/1 h algorithm had a higher positive predictive value for rule-in, whereas the extended algorithm had a higher negative predictive value for the rule-out. Similar findings emerged when using hs-cTn I.

 

CONCLUSIONS - The ESC hs-cTn 0/1 h algorithm better balanced efficacy and safety in the prediction of MACE, whereas the extended algorithm is the preferred option for the rule-out of 30-day MACE + UA. (Advantageous Predictors of Acute Coronary Syndromes Evaluation [APACE]; NCT00470587).