CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Uncovered Culprit Plaque Ruptures in Patients With ST-Segment Elevation Myocardial Infarction Assessed by Optical Coherence Tomography and Intravascular Ultrasound With iMap Consensus standards for acquisition, measurement, and reporting of intravascular optical coherence tomography studies: a report from the International Working Group for Intravascular Optical Coherence Tomography Standardization and Validation Covering our tracks – optical coherence tomography to assess vascular healing Double-Kiss-Crush Bifurcation Stenting: Step-by-Step Troubleshooting Chronic thromboembolic pulmonary hypertension Device specificity of vascular healing following implantation of bioresorbable vascular scaffolds and bioabsorbable polymer metallic drug-eluting stents in human coronary arteries: the ESTROFA OCT BVS vs. BP-DES study Elaborately Engineering a Self-Indicating Dual-Drug Nanoassembly for Site-Specific Photothermal-Potentiated Thrombus Penetration and Thrombolysis Refined balloon pulmonary angioplasty for inoperable patients with chronic thromboembolic pulmonary hypertension Long-term outcomes of routine versus provisional T-stenting for de novo coronary bifurcation lesions: five-year results of the Bifurcations Bad Krozingen I study Incidence of Adverse Events at 3 Months Versus at 12 Months After Dual Antiplatelet Therapy Cessation in Patients Treated With Thin Stents With Unprotected Left Main or Coronary Bifurcations

Original ResearchVolume 74, Issue 7, August 2019

JOURNAL:J Am Coll Cardiol. Article Link

Predicting Major Adverse Events in Patients With Acute Myocardial Infarction

T Nestelberger, J Boeddinghaus, the APACE Investigators et al. Keywords: acute myocardial infarction; clinical assessment; electrocardiography; high-sensitivity cardiac troponin; major adverse cardiac events

ABSTRACT


BACKGROUND- Early and accurate detection of short-term major adverse cardiac events (MACE) in patients with suspected acute myocardial infarction (AMI) is an unmet clinical need.

 

OBJECTIVES - The goal of this study was to test the hypothesis that adding clinical judgment and electrocardiogram findings to the European Society of Cardiology (ESC) high-sensitivity cardiac troponin (hs-cTn) measurement at presentation and after 1 h (ESC hs-cTn 0/1 h algorithm) would further improve its performance to predict MACE.

 

METHODS- Patients presenting to an emergency department with suspected AMI were enrolled in a prospective, multicenter diagnostic study. The primary endpoint was MACE, including all-cause death, cardiac arrest, AMI, cardiogenic shock, sustained ventricular arrhythmia, and high-grade atrioventricular block within 30 days including index events. The secondary endpoint was MACE + unstable angina (UA) receiving early (≤24 h) revascularization.

 

RESULTS- Among 3,123 patients, the ESC hs-cTnT 0/1 h algorithm triaged significantly more patients toward rule-out compared with the extended algorithm (60%; 95% CI: 59% to 62% vs. 45%; 95% CI: 43% to 46%; p < 0.001), while maintaining similar 30-day MACE rates (0.6%; 95% CI: 0.3% to 1.1% vs. 0.4%; 95% CI: 0.1% to 0.9%; p = 0.429), resulting in a similar negative predictive value (99.4%; 95% CI: 98.9% to 99.6% vs. 99.6%; 95% CI: 99.2% to 99.8%; p = 0.097). The ESC hs-cTnT 0/1 h algorithm ruled-in fewer patients (16%; 95% CI: 14.9% to 17.5% vs. 26%; 95% CI: 24.2% to 27.2%; p < 0.001) compared with the extended algorithm, albeit with a higher positive predictive value (76.6%; 95% CI: 72.8% to 80.1% vs. 59%; 95% CI: 55.5% to 62.3%; p < 0.001). For 30-day MACE + UA, the ESC hs-cTnT 0/1 h algorithm had a higher positive predictive value for rule-in, whereas the extended algorithm had a higher negative predictive value for the rule-out. Similar findings emerged when using hs-cTn I.

 

CONCLUSIONS - The ESC hs-cTn 0/1 h algorithm better balanced efficacy and safety in the prediction of MACE, whereas the extended algorithm is the preferred option for the rule-out of 30-day MACE + UA. (Advantageous Predictors of Acute Coronary Syndromes Evaluation [APACE]; NCT00470587).