CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Causes, Timing, and Impact of Dual Antiplatelet Therapy Interruption for Surgery (from the Patterns of Non-adherence to Anti-platelet Regimens In Stented Patients Registry) Transcatheter Versus Surgical Aortic Valve Replacement in Patients With Severe Aortic Valve Stenosis: 1-Year Results From the All-Comers NOTION Randomized Clinical Trial Ticagrelor with or without Aspirin in High-Risk Patients after PCI High-sensitivity troponin in the evaluation of patients with suspected acute coronary syndrome: a stepped-wedge, cluster-randomised controlled trial Incidence and prognostic implication of unrecognized myocardial scar characterized by cardiac magnetic resonance in diabetic patients without clinical evidence of myocardial infarction Multivessel PCI Guided by FFR or Angiography for Myocardial Infarction Imaging Coronary Anatomy and Reducing Myocardial Infarction Mortality in STEMI patients without standard modifiable risk factors: a sex-disaggregated analysis of SWEDEHEART registry data Interval From Initiation of Prasugrel to Coronary Angiography in Patients With Non–ST-Segment Elevation Myocardial Infarction A randomised trial comparing two stent sizing strategies in coronary bifurcation treatment with bioresorbable vascular scaffolds - The Absorb Bifurcation Coronary (ABC) trial

Original ResearchVolume 74, Issue 7, August 2019

JOURNAL:J Am Coll Cardiol. Article Link

Predicting Major Adverse Events in Patients With Acute Myocardial Infarction

T Nestelberger, J Boeddinghaus, the APACE Investigators et al. Keywords: acute myocardial infarction; clinical assessment; electrocardiography; high-sensitivity cardiac troponin; major adverse cardiac events

ABSTRACT


BACKGROUND- Early and accurate detection of short-term major adverse cardiac events (MACE) in patients with suspected acute myocardial infarction (AMI) is an unmet clinical need.

 

OBJECTIVES - The goal of this study was to test the hypothesis that adding clinical judgment and electrocardiogram findings to the European Society of Cardiology (ESC) high-sensitivity cardiac troponin (hs-cTn) measurement at presentation and after 1 h (ESC hs-cTn 0/1 h algorithm) would further improve its performance to predict MACE.

 

METHODS- Patients presenting to an emergency department with suspected AMI were enrolled in a prospective, multicenter diagnostic study. The primary endpoint was MACE, including all-cause death, cardiac arrest, AMI, cardiogenic shock, sustained ventricular arrhythmia, and high-grade atrioventricular block within 30 days including index events. The secondary endpoint was MACE + unstable angina (UA) receiving early (≤24 h) revascularization.

 

RESULTS- Among 3,123 patients, the ESC hs-cTnT 0/1 h algorithm triaged significantly more patients toward rule-out compared with the extended algorithm (60%; 95% CI: 59% to 62% vs. 45%; 95% CI: 43% to 46%; p < 0.001), while maintaining similar 30-day MACE rates (0.6%; 95% CI: 0.3% to 1.1% vs. 0.4%; 95% CI: 0.1% to 0.9%; p = 0.429), resulting in a similar negative predictive value (99.4%; 95% CI: 98.9% to 99.6% vs. 99.6%; 95% CI: 99.2% to 99.8%; p = 0.097). The ESC hs-cTnT 0/1 h algorithm ruled-in fewer patients (16%; 95% CI: 14.9% to 17.5% vs. 26%; 95% CI: 24.2% to 27.2%; p < 0.001) compared with the extended algorithm, albeit with a higher positive predictive value (76.6%; 95% CI: 72.8% to 80.1% vs. 59%; 95% CI: 55.5% to 62.3%; p < 0.001). For 30-day MACE + UA, the ESC hs-cTnT 0/1 h algorithm had a higher positive predictive value for rule-in, whereas the extended algorithm had a higher negative predictive value for the rule-out. Similar findings emerged when using hs-cTn I.

 

CONCLUSIONS - The ESC hs-cTn 0/1 h algorithm better balanced efficacy and safety in the prediction of MACE, whereas the extended algorithm is the preferred option for the rule-out of 30-day MACE + UA. (Advantageous Predictors of Acute Coronary Syndromes Evaluation [APACE]; NCT00470587).