CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Plaque composition by intravascular ultrasound and distal embolization after percutaneous coronary intervention Clinical impact of intravascular ultrasound-guided chronic total occlusion intervention with zotarolimus-eluting versus biolimus-eluting stent implantation: randomized study The pyruvate-lactate axis modulates cardiac hypertrophy and heart failure Cardiac Resynchronization Therapy in Inotrope-Dependent Heart Failure Patients - A Systematic Review and Meta-Analysis Association of Smoking Status With Long‐Term Mortality and Health Status After Transcatheter Aortic Valve Replacement: Insights From the Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy Registry Circulating sST2 and catestatin levels in patients with acute worsening of heart failure: a report from the CATSTAT-HF study Canagliflozin and Cardiovascular and Renal Events in Type 2 Diabetes Meta-analysis of outcomes after intravascular ultrasound-guided versus angiography-guided drug-eluting stent implantation in 26,503 patients enrolled in three randomized trials and 14 observational studies Role of Proximal Optimization Technique Guided by Intravascular Ultrasound on Stent Expansion, Stent Symmetry Index, and Side-Branch Hemodynamics in Patients With Coronary Bifurcation Lesions Fluid Volume Overload and Congestion in Heart Failure: Time to Reconsider Pathophysiology and How Volume Is Assessed

Original ResearchVolume 74, Issue 7, August 2019

JOURNAL:J Am Coll Cardiol. Article Link

Predicting Major Adverse Events in Patients With Acute Myocardial Infarction

T Nestelberger, J Boeddinghaus, the APACE Investigators et al. Keywords: acute myocardial infarction; clinical assessment; electrocardiography; high-sensitivity cardiac troponin; major adverse cardiac events

ABSTRACT


BACKGROUND- Early and accurate detection of short-term major adverse cardiac events (MACE) in patients with suspected acute myocardial infarction (AMI) is an unmet clinical need.

 

OBJECTIVES - The goal of this study was to test the hypothesis that adding clinical judgment and electrocardiogram findings to the European Society of Cardiology (ESC) high-sensitivity cardiac troponin (hs-cTn) measurement at presentation and after 1 h (ESC hs-cTn 0/1 h algorithm) would further improve its performance to predict MACE.

 

METHODS- Patients presenting to an emergency department with suspected AMI were enrolled in a prospective, multicenter diagnostic study. The primary endpoint was MACE, including all-cause death, cardiac arrest, AMI, cardiogenic shock, sustained ventricular arrhythmia, and high-grade atrioventricular block within 30 days including index events. The secondary endpoint was MACE + unstable angina (UA) receiving early (≤24 h) revascularization.

 

RESULTS- Among 3,123 patients, the ESC hs-cTnT 0/1 h algorithm triaged significantly more patients toward rule-out compared with the extended algorithm (60%; 95% CI: 59% to 62% vs. 45%; 95% CI: 43% to 46%; p < 0.001), while maintaining similar 30-day MACE rates (0.6%; 95% CI: 0.3% to 1.1% vs. 0.4%; 95% CI: 0.1% to 0.9%; p = 0.429), resulting in a similar negative predictive value (99.4%; 95% CI: 98.9% to 99.6% vs. 99.6%; 95% CI: 99.2% to 99.8%; p = 0.097). The ESC hs-cTnT 0/1 h algorithm ruled-in fewer patients (16%; 95% CI: 14.9% to 17.5% vs. 26%; 95% CI: 24.2% to 27.2%; p < 0.001) compared with the extended algorithm, albeit with a higher positive predictive value (76.6%; 95% CI: 72.8% to 80.1% vs. 59%; 95% CI: 55.5% to 62.3%; p < 0.001). For 30-day MACE + UA, the ESC hs-cTnT 0/1 h algorithm had a higher positive predictive value for rule-in, whereas the extended algorithm had a higher negative predictive value for the rule-out. Similar findings emerged when using hs-cTn I.

 

CONCLUSIONS - The ESC hs-cTn 0/1 h algorithm better balanced efficacy and safety in the prediction of MACE, whereas the extended algorithm is the preferred option for the rule-out of 30-day MACE + UA. (Advantageous Predictors of Acute Coronary Syndromes Evaluation [APACE]; NCT00470587).