CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Two-year outcomes following unprotected left main stenting with first vs new-generation drug-eluting stents: the FINE registry. EuroIntervention. Early Rhythm-Control Therapy in Patients with Atrial Fibrillation Impact of post-intervention minimal stent area on 9-month follow-up patency of paclitaxel-eluting stents: an integrated intravascular ultrasound analysis from the TAXUS IV, V, and VI and TAXUS ATLAS Workhorse, Long Lesion, and Direct Stent Trials Diagnostic accuracy of cardiac positron emission tomography versus single photon emission computed tomography for coronary artery disease: a bivariate meta-analysis Osteoarthritis risk is reduced after treatment with ticagrelor compared to clopidogrel: a propensity score matching analysis Meta-Analysis of Comparison of 5-Year Outcomes of Percutaneous Coronary Intervention Versus Coronary Artery Bypass Grafting in Patients With Unprotected Left Main Coronary Artery in the Era of Drug-eluting Stents Impact of Intravascular Ultrasound on Long-Term Clinical Outcomes in Patients With Acute Myocardial Infarction Valve‐in‐Valve for Degenerated Transcatheter Aortic Valve Replacement Versus Valve‐in‐Valve for Degenerated Surgical Aortic Bioprostheses: A 3‐Center Comparison of Hemodynamic and 1‐Year Outcome Second vs. First generation drug eluting stents in multiple vessel disease and left main stenosis: Two-year follow-up of the observational, prospective, controlled, and multicenter ERACI IV registry Clinical Outcome After DK Crush Versus Culotte Stenting of Distal Left Main Bifurcation Lesions: The 3-Year Follow-Up Results of the DKCRUSH-III Study

Original ResearchVolume 74, Issue 9, September 2019

JOURNAL:J Am Coll Cardiol. Article Link

Anticoagulation After Surgical or Transcatheter Bioprosthetic Aortic Valve Replacement

T Chakravarty, A Patel, S Kapadia et al. Keywords: anticoagulation; bioprosthetic aortic valve replacement; transcatheter aortic valve replacement

ABSTRACT


BACKGROUND- There is paucity of evidence on the impact of anticoagulation (AC) after bioprosthetic aortic valve replacement (AVR) on valve hemodynamics and clinical outcomes.

 

OBJECTIVES- The study aimed to assess the impact of AC after bioprosthetic AVR on valve hemodynamics and clinical outcomes.

 

METHODS- Data on antiplatelet and antithrombotic therapy were collected. Echocardiograms were performed at 30 days and 1 year post-AVR. Linear regression model and propensity-score adjusted cox proportional model were used to assess the impact of AC on valve hemodynamics and clinical outcomes, respectively.

 

RESULTS- A total of 4,832 patients undergoing bioprosthetic AVR (transcatheter aortic valve replacement [TAVR], n = 3,889 and surgical AVR [SAVR], n = 943) in the pooled cohort of PARTNER2 (Placement of Aortic Transcatheter Valves) randomized trials and nonrandomized registries were studied. Following adjustment for valve size, annular diameter, atrial fibrillation, and ejection fraction at the time of assessment of hemodynamics, there was no significant difference in aortic valve mean gradients or aortic valve areas between patients discharged on AC vs. those not discharged on AC, for either TAVR or SAVR cohorts. A significantly greater proportion of patients not discharged on AC had an increase in mean gradient >10 mm Hg from 30 days to 1 year, compared with those discharged on AC (2.3% vs. 1.1%, p = 0.03). There was no independent association between AC after TAVR and adverse outcomes (death, p = 0.15; rehospitalization, p = 0.16), whereas AC after SAVR was associated with significantly fewer strokes (hazard ratio [HR]: 0.17; 95% confidence interval [CI]: 0.050.60; p = 0.006).

 

CONCLUSIONS- In the short term, early AC after bioprosthetic AVR did not result in adverse clinical events, did not significantly affect aortic valve hemodynamics (aortic valve gradients or area), and was associated with decreased rates of stroke after SAVR (but not after TAVR). Whether early AC after bioprosthetic AVR has impact on long-term outcomes remains to be determined. (Placement of AoRTic TraNscathetER Valves [PARTNERII A]; NCT01314313)