CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

In vitro flow and optical coherence tomography comparison of two bailout techniques after failed provisional stenting for bifurcation percutaneous coronary interventions Pancoronary Plaque Characteristics in STEMI Caused by Culprit Plaque Erosion Versus Rupture: 3-Vessel OCT Study Pulmonary hypertension related to congenital heart disease: a call for action Survival prospects of treatment naïve patients with Eisenmenger: a systematic review of the literature and report of own experience C-reactive protein and prognosis after percutaneous coronary intervention and bypass graft surgery for left main coronary artery disease: Analysis from the EXCEL trial ACCF/AHA 2009 expert consensus document on pulmonary hypertension a report of the American College of Cardiology Foundation Task Force on Expert Consensus Documents and the American Heart Association developed in collaboration with the American College of Chest Physicians; American Thoracic Society, Inc.; and the Pulmonary Hypertension Association Transthoracic echocardiography for the evaluation of children and adolescents with suspected or confirmed pulmonary hypertension. Expert consensus statement on the diagnosis and treatment of paediatric pulmonary hypertension. The European Paediatric Pulmonary Vascular Disease Network, endorsed by ISHLT and D6PK Dual Antiplatelet Therapy after PCI in Patients at High Bleeding Risk Comprehensive Management of Cardiovascular Risk Factors for Adults With Type 2 Diabetes: A Scientific Statement From the American Heart Association Attenuated Mitral Leaflet Enlargement Contributes to Functional Mitral Regurgitation After Myocardial Infarction

Original ResearchVolume 74, Issue 9, September 2019

JOURNAL:J Am Coll Cardiol. Article Link

Anticoagulation After Surgical or Transcatheter Bioprosthetic Aortic Valve Replacement

T Chakravarty, A Patel, S Kapadia et al. Keywords: anticoagulation; bioprosthetic aortic valve replacement; transcatheter aortic valve replacement

ABSTRACT


BACKGROUND- There is paucity of evidence on the impact of anticoagulation (AC) after bioprosthetic aortic valve replacement (AVR) on valve hemodynamics and clinical outcomes.

 

OBJECTIVES- The study aimed to assess the impact of AC after bioprosthetic AVR on valve hemodynamics and clinical outcomes.

 

METHODS- Data on antiplatelet and antithrombotic therapy were collected. Echocardiograms were performed at 30 days and 1 year post-AVR. Linear regression model and propensity-score adjusted cox proportional model were used to assess the impact of AC on valve hemodynamics and clinical outcomes, respectively.

 

RESULTS- A total of 4,832 patients undergoing bioprosthetic AVR (transcatheter aortic valve replacement [TAVR], n = 3,889 and surgical AVR [SAVR], n = 943) in the pooled cohort of PARTNER2 (Placement of Aortic Transcatheter Valves) randomized trials and nonrandomized registries were studied. Following adjustment for valve size, annular diameter, atrial fibrillation, and ejection fraction at the time of assessment of hemodynamics, there was no significant difference in aortic valve mean gradients or aortic valve areas between patients discharged on AC vs. those not discharged on AC, for either TAVR or SAVR cohorts. A significantly greater proportion of patients not discharged on AC had an increase in mean gradient >10 mm Hg from 30 days to 1 year, compared with those discharged on AC (2.3% vs. 1.1%, p = 0.03). There was no independent association between AC after TAVR and adverse outcomes (death, p = 0.15; rehospitalization, p = 0.16), whereas AC after SAVR was associated with significantly fewer strokes (hazard ratio [HR]: 0.17; 95% confidence interval [CI]: 0.050.60; p = 0.006).

 

CONCLUSIONS- In the short term, early AC after bioprosthetic AVR did not result in adverse clinical events, did not significantly affect aortic valve hemodynamics (aortic valve gradients or area), and was associated with decreased rates of stroke after SAVR (but not after TAVR). Whether early AC after bioprosthetic AVR has impact on long-term outcomes remains to be determined. (Placement of AoRTic TraNscathetER Valves [PARTNERII A]; NCT01314313)