CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Two-year outcomes following unprotected left main stenting with first vs new-generation drug-eluting stents: the FINE registry. EuroIntervention. Early Rhythm-Control Therapy in Patients with Atrial Fibrillation Impact of post-intervention minimal stent area on 9-month follow-up patency of paclitaxel-eluting stents: an integrated intravascular ultrasound analysis from the TAXUS IV, V, and VI and TAXUS ATLAS Workhorse, Long Lesion, and Direct Stent Trials Diagnostic accuracy of cardiac positron emission tomography versus single photon emission computed tomography for coronary artery disease: a bivariate meta-analysis Osteoarthritis risk is reduced after treatment with ticagrelor compared to clopidogrel: a propensity score matching analysis Meta-Analysis of Comparison of 5-Year Outcomes of Percutaneous Coronary Intervention Versus Coronary Artery Bypass Grafting in Patients With Unprotected Left Main Coronary Artery in the Era of Drug-eluting Stents Impact of Intravascular Ultrasound on Long-Term Clinical Outcomes in Patients With Acute Myocardial Infarction Valve‐in‐Valve for Degenerated Transcatheter Aortic Valve Replacement Versus Valve‐in‐Valve for Degenerated Surgical Aortic Bioprostheses: A 3‐Center Comparison of Hemodynamic and 1‐Year Outcome Second vs. First generation drug eluting stents in multiple vessel disease and left main stenosis: Two-year follow-up of the observational, prospective, controlled, and multicenter ERACI IV registry Clinical Outcome After DK Crush Versus Culotte Stenting of Distal Left Main Bifurcation Lesions: The 3-Year Follow-Up Results of the DKCRUSH-III Study

Clinical Trial2017 Dec;354(6):553-560

JOURNAL:Am J Med Sci. Article Link

Drug-Coated Balloon Versus Drug-Eluting Stent in Primary Percutaneous Coronary Intervention: A Feasibility Study

Gobić D, Tomulić V, Lulić D et al. Keywords: Angioplasty; Balloon dilation; Coronary; Drug-eluting stents; Myocardial infarction; Percutaneous coronary intervention

ABSTRACT



BACKGROUND - Drug-eluting stents (DES) represent a significant evolution in the treatment of patients with acute myocardial infarction with ST elevation. However, stent-related adverse events have led to an introduction of drug-coated balloons (DCB) applied particularly to bifurcation lesions, in-stent restenosis and small vessel disease. The aim of this study was to determine whether a DCB-only strategy has a similar safety profile and equal angiographic and clinical outcomes to DES implantation in primary percutaneous coronary intervention (pPCI).


MATERIALS AND METHODS - Seventy-five patients with acute myocardial infarction with ST elevation were randomized into DES and DCB groups of 37 and 38 patients, respectively. The study end-points were major adverse cardiac events and late lumen loss during the 6 months following the pPCI.


RESULTS - Reinfarction occurred in 5.4% of patients in the DES and 5.3% of patients in the DCB group after 1 month (risk ratio = 1.03, 95% CI [0.15-6.91], P = 0.98). After 6 months, major adverse cardiac events were reported in 5.4% of patients in the DES group and none in the DCB group (risk ratio = 5.13, 95% CI [0.25-103.42], P = 0.29). Late lumen loss in the DES group was 0.10 ± 0.19mm and -0.09 ± 0.09mm in the DCB group (P < 0.05).


CONCLUSIONS - A DCB-only strategy is safe and feasible in the pPCI setting and showed good clinical and angiographic outcomes in a 6-month follow-up period.


Copyright © 2017 Southern Society for Clinical Investigation. Published by Elsevier Inc. All rights reserved.