Clinical impact of intravascular ultrasound guidance in drug-eluting stent implantation for unprotected left main coronary disease: pooled analysis at the patient-level of 4 registries Fractional flow reserve derived from CCTA may have a prognostic role in myocardial bridging Impact of plaque components on no-reflow phenomenon after stent deployment in patients with acute coronary syndrome: a virtual histology-intravascular ultrasound analysis Prdm16 Deficiency Leads to Age-Dependent Cardiac Hypertrophy, Adverse Remodeling, Mitochondrial Dysfunction, and Heart Failure How to diagnose heart failure with preserved ejection fraction: the HFA-PEFF diagnostic algorithm: a consensus recommendation from the Heart Failure Association (HFA) of the European Society of Cardiology (ESC) Percutaneous coronary intervention versus coronary artery bypass grafting in patients with three-vessel or left main coronary artery disease: 10-year follow-up of the multicentre randomised controlled SYNTAX trial The Utility of Contrast Medium Fractional Flow Reserve in Functional Assessment Of Coronary Disease in Daily Practice Attenuated plaque detected by intravascular ultrasound: clinical, angiographic, and morphologic features and post-percutaneous coronary intervention complications in patients with acute coronary syndromes Nitrosative stress drives heart failure with preserved ejection fraction Impact of the Use of Intravascular Imaging on Patients Who Underwent Orbital Atherectomy

Clinical Trial2017 Dec;354(6):553-560

JOURNAL:Am J Med Sci. Article Link

Drug-Coated Balloon Versus Drug-Eluting Stent in Primary Percutaneous Coronary Intervention: A Feasibility Study

Gobić D, Tomulić V, Lulić D et al. Keywords: Angioplasty; Balloon dilation; Coronary; Drug-eluting stents; Myocardial infarction; Percutaneous coronary intervention

ABSTRACT



BACKGROUND - Drug-eluting stents (DES) represent a significant evolution in the treatment of patients with acute myocardial infarction with ST elevation. However, stent-related adverse events have led to an introduction of drug-coated balloons (DCB) applied particularly to bifurcation lesions, in-stent restenosis and small vessel disease. The aim of this study was to determine whether a DCB-only strategy has a similar safety profile and equal angiographic and clinical outcomes to DES implantation in primary percutaneous coronary intervention (pPCI).


MATERIALS AND METHODS - Seventy-five patients with acute myocardial infarction with ST elevation were randomized into DES and DCB groups of 37 and 38 patients, respectively. The study end-points were major adverse cardiac events and late lumen loss during the 6 months following the pPCI.


RESULTS - Reinfarction occurred in 5.4% of patients in the DES and 5.3% of patients in the DCB group after 1 month (risk ratio = 1.03, 95% CI [0.15-6.91], P = 0.98). After 6 months, major adverse cardiac events were reported in 5.4% of patients in the DES group and none in the DCB group (risk ratio = 5.13, 95% CI [0.25-103.42], P = 0.29). Late lumen loss in the DES group was 0.10 ± 0.19mm and -0.09 ± 0.09mm in the DCB group (P < 0.05).


CONCLUSIONS - A DCB-only strategy is safe and feasible in the pPCI setting and showed good clinical and angiographic outcomes in a 6-month follow-up period.


Copyright © 2017 Southern Society for Clinical Investigation. Published by Elsevier Inc. All rights reserved.