CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Survival After Coronary Revascularization With Paclitaxel-Coated Balloons 3-Year Clinical Follow-Up of the RIBS IV Clinical Trial A Prospective Randomized Study of Drug-Eluting Balloons Versus Everolimus-Eluting Stents in Patients With In-Stent Restenosis in Coronary Arteries Previously Treated With Drug-Eluting Stents Mechanistic Biomarkers Informative of Both Cancer and Cardiovascular Disease: JACC State-of-the-Art Review Percutaneous Left Atrial Appendage Transcatheter Occlusion (PLAATO System) to Prevent Stroke in High-Risk Patients With Non-Rheumatic Atrial Fibrillation: Results From the International Multi-Center Feasibility Trials Initial Worldwide Experience With the WATCHMAN Left Atrial Appendage System for Stroke Prevention in Atrial Fibrillation 5-Year Outcomes of PCI Guided by Measurement of Instantaneous Wave-Free Ratio Versus Fractional Flow Reserve Thrombotic Risk and Antithrombotic Strategies After Transcatheter Mitral Valve Replacement Pathophysiology, diagnosis and new therapeutic approaches for ischemic mitral regurgitation Transcatheter Interventions for Mitral Regurgitation: Multimodality Imaging for Patient Selection and Procedural Guidance 2022 ESC/ERS Guidelines for the diagnosis and treatment of pulmonary hypertension

Original Research2017 Nov 28 [Epub ahead of print]

JOURNAL:Int J Cardiol. Article Link

Comparative efficacy of two paclitaxel-coated balloons with different excipient coatings in patients with coronary in-stent restenosis: A pooled analysis of the Intracoronary Stenting and Angiographic Results: Optimizing Treatment of Drug Eluting Stent In-Stent Restenosis 3 and 4 trials

Colleran R, Joner M, ISAR-DESIRE 3 and ISAR-DESIRE 4 investigators Keywords: Angiographic follow-up; Drug-coated balloon; In-stent restenosis; Paclitaxel-coated balloon

ABSTRACT


BACKGROUND - Angioplasty with paclitaxel-coated balloons (PCB) is recommended for treatment of patients with coronary in-stent restenosis (ISR) according to European clinical practice guidelines. Most clinical trials have investigated iopromide-based PCB and there is a paucity of data comparing efficacy against butyryl-tri-hexyl citrate (BTHC)-based PCB. Our aim was to compare the performance of two widely-used PCB in the treatment of coronary ISR.


METHODS - We analysed patients treated with BTHC- or iopromide-PCB for treatment of drug-eluting stent ISR in the setting of 2 consecutive trials with identical inclusion and exclusion criteria. The primary endpoint was diameter stenosis at 6-8month angiographic surveillance. The secondary endpoint of interest was the composite of death, myocardial infarction (MI) or target-lesion revascularisation (TLR) at 1year. Multivariate analysis was performed to adjust for differences in baseline characteristics between groups.


RESULTS - In total, 264 patients were treated with BTHC-PCB (n=127) or iopromide-PCB (n=137). Baseline patient characteristics were similar for both groups. Post-procedure stenosis was slightly larger with BTHC-PCB (22.3 [SD 8.2]% vs. 18.4 [SD 9.9]%, P=0.001). At 6-8month angiography, diameter stenosis was 40.4 [SD 21.9]% vs. 37.4 [SD 21.4]% in the BTHC-PCB and iopromide-PCB groups, respectively (P=0.16, Padjusted=0.32). At 1year, death, MI or TLR occurred in 29 (23.2%) vs. 32 (23.4%) patients in the BTHC-PCB and iopromide-PCB groups, respectively (HR 1.03 [95% CI 0.62-1.70], P=0.91, Padjusted=0.96).


CONCLUSIONS - In patients undergoing intervention for ISR, angioplasty with BTHC-PCB showed similar angiographic and clinical results at 1year compared with iopromide-PCB.


Copyright © 2017. Published by Elsevier B.V.