CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Anticoagulation After Surgical or Transcatheter Bioprosthetic Aortic Valve Replacement Myocardial bridging of the left anterior descending coronary artery is associated with reduced myocardial perfusion reserve: a 13N-ammonia PET study Differential prognostic effect of intravascular ultrasound use according to implanted stent length The Science Underlying COVID-19: Implications for the Cardiovascular System The contribution of tissue-grouped BMI-associated gene sets to cardiometabolic-disease risk: a Mendelian randomization study Differential Impact of Heart Failure With Reduced Ejection Fraction on Men and Women Management of Asymptomatic Severe Aortic Stenosis: Evolving Concepts in Timing of Valve Replacement Transcatheter Versus Surgical Aortic Valve Replacement in Low-Risk Patients Individualized antiplatelet therapy after drug-eluting stent deployment: Implication of clinical trials of different durations of dual antiplatelet therapy Non-invasive detection of coronary inflammation using computed tomography and prediction of residual cardiovascular risk (the CRISP CT study): a post-hoc analysis of prospective outcome data

Original ResearchVolume 74, Issue 13 Supplement, October 2019

JOURNAL:J Am Coll Cardiol. Article Link

Impact of Intravascular Ultrasound-Guided Drug-Eluting Stent Implantation on Patients With Chronic Kidney Disease: Subgroup Analysis From ULTIMATE Trial

JJ Zhang, XF Gao, the ULTIMATE Investigators. Keywords: IVUS guidance vs angiography guidance; TVF; CKD

ABSTRACT


BACKGROUND - Patients with chronic kidney disease (CKD) present more frequently with complex and extensive lesions, and intravascular ultrasound (IVUS)–guided drug-eluting stent (DES) implantation is associated with improved clinical outcomes in complex lesions. However, it still remains controversial that routine IVUS guidance could be beneficial to CKD patients.


METHODS - This study aimed to investigate the impact of IVUS- or angiography-guided DES implantation on patients with CKD based on the database from the ULTIMATE trial.


RESULTS - Estimated glomerular filtration rate (eGFR) was available in 1,443 patients, with mean eGFR 81.41 ± 28.92 ml/min/1.73 m2, of whom 723 were in the IVUS guidance group and 720 in the angiography guidance group. Finally, CKD was present in 349 (24.2%) patients. At 12 months, the target vessel failure (TVF) in the CKD group was 7.2%, significantly higher than 3.2% in the no CKD group (hazard ratio [HR]: 2.30; 95% CI: 1.38 to 3.84; p = 0.001), mainly driven by increased risk of cardiac death (2.9% vs. 0.5%; p < 0.001) in CKD patients. Moreover, there were 25 TVFs in CKD patients, with 7 (3.9%) in the IVUS group and 18 (10.7%) in the angiography group (HR: 0.35; 95% CI: 0.15 to 0.84; p = 0.01) (Figure), while 35 TVFs occurred in patients without CKD, with 14 (2.6%) in the IVUS group and 21 (3.8%) in the angiography group (HR: 0.67; 95% CI: 0.34 to 1.32; p = 0.25; p for interaction = 0.24). The reduced risk of TVF in the IVUS group for CKD patients was mainly driven by the lower risk of TVMI (0.6% vs. 3.6%; borderline p = 0.05) and TVR (1.1% vs. 4.7; p = 0.04).


CONCLUSION - The present study demonstrated that CKD patients undergoing DES implantation had a higher risk of TVF during 12 months of follow-up. More importantly, the risk of TVF in CKD patients could be significantly decreased through IVUS guidance compared with angiography guidance.