Comparison of Outcomes of Percutaneous Coronary Intervention on Native Coronary Arteries Versus on Saphenous Venous Aorta Coronary Conduits in Patients With Low Left Ventricular Ejection Fraction and Impella Device Implantation Achieved or Attempted (from the PROTECT II Randomized Trial and the cVAD Registry) Effect of the PCSK9 Inhibitor Evolocumab on Total Cardiovascular Events in Patients With Cardiovascular DiseaseA Prespecified Analysis From the FOURIER Trial Revascularization in Patients With Left Main Coronary Artery Disease and Left Ventricular Dysfunction Long-Term Outcomes After PCI or CABG for Left Main Coronary Artery Disease According to Lesion Location Comparison of Early Surgical or Transcatheter Aortic Valve Replacement Versus Conservative Management in Low-Flow, Low-Gradient Aortic Stenosis Using Inverse Probability of Treatment Weighting: Results From the TOPAS Prospective Observational Cohort Study Transcatheter Aortic Valve Replacement in Low-Risk Patients With Symptomatic Severe Bicuspid Aortic Valve Stenosis Transcatheter Versus Surgical Aortic Valve Replacement in Low-Risk Patients Right ventricular function and outcome in patients undergoing transcatheter aortic valve replacement 5-Year Outcomes After TAVR With Balloon-Expandable Versus Self-Expanding Valves: Results From the CHOICE Randomized Clinical Trial Stroke Rates Following Surgical Versus Percutaneous Coronary Revascularization

Clinical TrialVolume 12, Issue 24, December 2019

JOURNAL:JACC Cardiovasc Interv. Article Link

Left Ventricular Rapid Pacing Via the Valve Delivery Guidewire in Transcatheter Aortic Valve Replacement

Benjamin Faurie, Géraud Souteyrand, the EASY TAVI Investigators. Keywords: left ventricular pacing; left ventricular stimulation; transcatheter aortic valve implantation; transcatheter aortic valve replacement

ABSTRACT

OBJECTIVES -  This study investigated whether left ventricular (LV) stimulation via a guidewire-reduced procedure duration while maintaining efficacy and safety compared with standard right ventricular (RV) stimulation.

 

BACKGROUND -  Rapid ventricular pacing is necessary to ensure cardiac standstill during transcatheter aortic valve replacement (TAVR).

 

METHODS -  This is a prospective, multicenter, single-blinded, superiority, randomized controlled trial. Patients undergoing transfemoral TAVR with a SAPIEN valve (Edwards Lifesciences, Irvine, California) were allocated to LV or RV stimulation. The primary endpoint was procedure duration. Secondary endpoints included efficacy, safety, and cost at 30 days.

 

RESULTS -  Between May 2017 and May 2018, 307 patients were randomized, but 4 were excluded because they did not receive the intended treatment: 303 patients were analyzed in the LV (n = 151) or RV (n = 152) stimulation groups. Mean procedure duration was significantly shorter in the LV stimulation group (48.4 ± 16.9 min vs. 55.6 ± 26.9 min; p = 0.0013), with a difference of 0.12 (95% confidence interval: 0.20 to 0.05) in the log-transformed procedure duration (p = 0.0012). Effective stimulation was similar in the LV and RV stimulation groups: 124 (84.9%) versus 128 (87.1%) (p = 0.60). Safety of stimulation was also similar in the LV and RV stimulation groups: procedural success occurred in 151 (100%) versus 151 (99.3%) patients (p = 0.99); 30-day MACE-TAVR (major adverse cardiovascular event-transcatheter aortic valve replacement) occurred in 21 (13.9%) versus 26 (17.1%) patients (p = 0.44); fluoroscopy time (min) was lower in the LV stimulation group (13.48 ± 5.98 vs. 14.60 ± 5.59; p = 0.02), as was cost (18,807 ± 1,318 vs. 19,437 ± 2,318; p = 0.001).

 

CONCLUSIONS - Compared with RV stimulation, LV stimulation during TAVR was associated with significantly reduced procedure duration, fluoroscopy time, and cost, with similar efficacy and safety. (Direct Left Ventricular Rapid Pacing Via the Valve Delivery Guide-wire in TAVR [EASY TAVI]; NCT02781896)