CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

New Volumetric Analysis Method for Stent Expansion and its Correlation With Final Fractional Flow Reserve and Clinical Outcome An ILUMIEN I Substudy ACCF/AHA 2009 expert consensus document on pulmonary hypertension a report of the American College of Cardiology Foundation Task Force on Expert Consensus Documents and the American Heart Association developed in collaboration with the American College of Chest Physicians; American Thoracic Society, Inc.; and the Pulmonary Hypertension Association Fractional Flow Reserve-Guided Complete Revascularization Improves the Prognosis in Patients With ST-Segment-Elevation Myocardial Infarction and Severe Nonculprit Disease: A DANAMI 3-PRIMULTI Substudy (Primary PCI in Patients With ST-Elevation Myocardial Infarction and Multivessel Disease: Treatment Dual Antiplatelet Therapy after PCI in Patients at High Bleeding Risk Diagnosis and management of acute deep vein thrombosis: a joint consensus document from the European Society of Cardiology working groups of aorta and peripheral vascular diseases and pulmonary circulation and right ventricular function 2-Year Outcomes After Transcatheter Versus Surgical Aortic Valve Replacement in Low-Risk Patients 中国肺动脉高压诊断与治疗指南(2021版) Edoxaban versus Dual Antiplatelet Therapy for Leaflet Thrombosis and Cerebral Thromboembolism after TAVR: The ADAPT-TAVR Randomized Clinical Trial Bosentan therapy in patients with Eisenmenger syndrome: a multicenter, double-blind, randomized, placebo-controlled study Minimum Core Data Elements for Evaluation of TAVR: A Scientific Statement by PASSION CV, HVC, and TVT Registry

Clinical TrialVolume 12, Issue 24, December 2019

JOURNAL:JACC Cardiovasc Interv. Article Link

Left Ventricular Rapid Pacing Via the Valve Delivery Guidewire in Transcatheter Aortic Valve Replacement

Benjamin Faurie, Géraud Souteyrand, the EASY TAVI Investigators. Keywords: left ventricular pacing; left ventricular stimulation; transcatheter aortic valve implantation; transcatheter aortic valve replacement

ABSTRACT

OBJECTIVES -  This study investigated whether left ventricular (LV) stimulation via a guidewire-reduced procedure duration while maintaining efficacy and safety compared with standard right ventricular (RV) stimulation.

 

BACKGROUND -  Rapid ventricular pacing is necessary to ensure cardiac standstill during transcatheter aortic valve replacement (TAVR).

 

METHODS -  This is a prospective, multicenter, single-blinded, superiority, randomized controlled trial. Patients undergoing transfemoral TAVR with a SAPIEN valve (Edwards Lifesciences, Irvine, California) were allocated to LV or RV stimulation. The primary endpoint was procedure duration. Secondary endpoints included efficacy, safety, and cost at 30 days.

 

RESULTS -  Between May 2017 and May 2018, 307 patients were randomized, but 4 were excluded because they did not receive the intended treatment: 303 patients were analyzed in the LV (n = 151) or RV (n = 152) stimulation groups. Mean procedure duration was significantly shorter in the LV stimulation group (48.4 ± 16.9 min vs. 55.6 ± 26.9 min; p = 0.0013), with a difference of 0.12 (95% confidence interval: 0.20 to 0.05) in the log-transformed procedure duration (p = 0.0012). Effective stimulation was similar in the LV and RV stimulation groups: 124 (84.9%) versus 128 (87.1%) (p = 0.60). Safety of stimulation was also similar in the LV and RV stimulation groups: procedural success occurred in 151 (100%) versus 151 (99.3%) patients (p = 0.99); 30-day MACE-TAVR (major adverse cardiovascular event-transcatheter aortic valve replacement) occurred in 21 (13.9%) versus 26 (17.1%) patients (p = 0.44); fluoroscopy time (min) was lower in the LV stimulation group (13.48 ± 5.98 vs. 14.60 ± 5.59; p = 0.02), as was cost (18,807 ± 1,318 vs. 19,437 ± 2,318; p = 0.001).

 

CONCLUSIONS - Compared with RV stimulation, LV stimulation during TAVR was associated with significantly reduced procedure duration, fluoroscopy time, and cost, with similar efficacy and safety. (Direct Left Ventricular Rapid Pacing Via the Valve Delivery Guide-wire in TAVR [EASY TAVI]; NCT02781896)