Titration of Medical Therapy for Heart Failure With Reduced Ejection Fraction Optical Frequency Domain Imaging Versus Intravascular Ultrasound in Percutaneous Coronary Intervention (OPINION Trial) Results From the OPINION Imaging Study Impact of plaque components on no-reflow phenomenon after stent deployment in patients with acute coronary syndrome: a virtual histology-intravascular ultrasound analysis Myofibroblast Phenotype and Reversibility of Fibrosis in Patients With End-Stage Heart Failure H2FPEF Score for Predicting Future Heart Failure in Stable Outpatients With Cardiovascular Risk Factors Clinical use of intracoronary imaging. Part 1: guidance and optimization of coronary interventions. An expert consensus document of the European Association of Percutaneous Cardiovascular Interventions: Endorsed by the Chinese Society of Cardiology Frailty Is Intertwined With Heart Failure: Mechanisms, Prevalence, Prognosis, Assessment, and Management Effect of Ticagrelor Monotherapy vs Ticagrelor With Aspirin on Major Bleeding and Cardiovascular Events in Patients With Acute Coronary Syndrome: The TICO Randomized Clinical Trial Clinical trial design and rationale of the Multicenter Study of MagLev Technology in Patients Undergoing Mechanical Circulatory Support Therapy With HeartMate 3 (MOMENTUM 3) investigational device exemption clinical study protocol 6- Versus 24-Month Dual Antiplatelet Therapy After Implantation of Drug-Eluting Stents in Patients Nonresistant to Aspirin Final Results of the ITALIC Trial (Is There a Life for DES After Discontinuation of Clopidogrel)

Clinical TrialVolume 12, Issue 24, December 2019

JOURNAL:JACC Cardiovasc Interv. Article Link

Left Ventricular Rapid Pacing Via the Valve Delivery Guidewire in Transcatheter Aortic Valve Replacement

Benjamin Faurie, Géraud Souteyrand, the EASY TAVI Investigators. Keywords: left ventricular pacing; left ventricular stimulation; transcatheter aortic valve implantation; transcatheter aortic valve replacement

ABSTRACT

OBJECTIVES -  This study investigated whether left ventricular (LV) stimulation via a guidewire-reduced procedure duration while maintaining efficacy and safety compared with standard right ventricular (RV) stimulation.

 

BACKGROUND -  Rapid ventricular pacing is necessary to ensure cardiac standstill during transcatheter aortic valve replacement (TAVR).

 

METHODS -  This is a prospective, multicenter, single-blinded, superiority, randomized controlled trial. Patients undergoing transfemoral TAVR with a SAPIEN valve (Edwards Lifesciences, Irvine, California) were allocated to LV or RV stimulation. The primary endpoint was procedure duration. Secondary endpoints included efficacy, safety, and cost at 30 days.

 

RESULTS -  Between May 2017 and May 2018, 307 patients were randomized, but 4 were excluded because they did not receive the intended treatment: 303 patients were analyzed in the LV (n = 151) or RV (n = 152) stimulation groups. Mean procedure duration was significantly shorter in the LV stimulation group (48.4 ± 16.9 min vs. 55.6 ± 26.9 min; p = 0.0013), with a difference of 0.12 (95% confidence interval: 0.20 to 0.05) in the log-transformed procedure duration (p = 0.0012). Effective stimulation was similar in the LV and RV stimulation groups: 124 (84.9%) versus 128 (87.1%) (p = 0.60). Safety of stimulation was also similar in the LV and RV stimulation groups: procedural success occurred in 151 (100%) versus 151 (99.3%) patients (p = 0.99); 30-day MACE-TAVR (major adverse cardiovascular event-transcatheter aortic valve replacement) occurred in 21 (13.9%) versus 26 (17.1%) patients (p = 0.44); fluoroscopy time (min) was lower in the LV stimulation group (13.48 ± 5.98 vs. 14.60 ± 5.59; p = 0.02), as was cost (18,807 ± 1,318 vs. 19,437 ± 2,318; p = 0.001).

 

CONCLUSIONS - Compared with RV stimulation, LV stimulation during TAVR was associated with significantly reduced procedure duration, fluoroscopy time, and cost, with similar efficacy and safety. (Direct Left Ventricular Rapid Pacing Via the Valve Delivery Guide-wire in TAVR [EASY TAVI]; NCT02781896)