CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Randomized comparison of clinical outcomes between intravascular ultrasound and angiography-guided drug-eluting stent implantation for long coronary artery stenoses Lifestyle Modifications for Preventing and Treating Heart Failure Delirium After TAVR: Crosspassing the Limit of Resilience Longitudinal Change in Galectin-3 and Incident Cardiovascular Outcomes Cardiac resynchronization therapy with a defibrillator (CRTd) in failing heart patients with type 2 diabetes mellitus and treated by glucagon-like peptide 1 receptor agonists (GLP-1 RA) therapy vs. conventional hypoglycemic drugs: arrhythmic burden, hospitalizations for heart failure, and CRTd responders rate Summary of Updated Recommendations for Primary Prevention of Cardiovascular Disease in Women: JACC State-of-the-Art Review Heart Failure With Recovered Left Ventricular Ejection Fraction: JACC Scientific Expert Panel Metformin Lowers Body Weight But Fails to Increase Insulin Sensitivity in Chronic Heart Failure Patients without Diabetes: a Randomized, Double-Blind, Placebo-Controlled Study American College of Cardiology Clinical Expert Consensus Document on Standards for Acquisition, Measurement and Reporting of Intravascular Ultrasound Studies (IVUS). A report of the American College of Cardiology Task Force on Clinical Expert Consensus Documents From Detecting the Vulnerable Plaque to Managing the Vulnerable Patient

Original Research2019 Nov 23 [Online ahead of print]

JOURNAL:J Am Coll Cardiol. Article Link

Incidence of Adverse Events at 3 Months Versus at 12 Months After Dual Antiplatelet Therapy Cessation in Patients Treated With Thin Stents With Unprotected Left Main or Coronary Bifurcations

F D'Ascenzo, U Barbero, M Abdirashid et al. Keywords: DAPT cessation; shorter DAPT vs intermediate DAPT vs long DAPT;

ABSTRACT


Incidence and predictors of adverse events after dual antiplatelet therapy (DAPT) cessation in patients treated with thin stents (<100 microns) in unprotected left main (ULM) or coronary bifurcation remain undefined. All consecutive patients presenting with a critical lesion of an ULM or involving a main coronary bifurcation who were treated with very thin strut stents were included. MACE (a composite end point of cardiovascular death, myocardial infarction [MI], target lesion revascularization [TLR], and stent thrombosis [ST]) was the primary endpoint, whereas target vessel revascularization (TVR) was the secondary endpoint, with particular attention to type and occurrence of ST and occurrence of ST, CV death, and MI during DAPT or after DAPT discontinuation. All analyses were performed according to length of DAPT dividing the patients in 3 groups: Short DAPT (3-months), intermediate DAPT (3 to 12 months), and long DAPT (12-months). A total of 117 patients were discharged with an indication for DAPT ≤3 months (median 1: 1 to 2.5), 200 for DAPT between 3 and 12 months (median 8: 7 to 10), and 1,958 with 12 months DAPT. After 12.8 months (8 to 20), MACE was significantly higher in the 3-month group compared with 3 to 12 and 12-month groups (9.4% vs 4.0% vs 7.2%, p ≤0.001), mainly driven by MI (4.4% vs 1.5% vs 3%, p ≤0.001) and overall ST (4.3% vs 1.5% vs 1.8%, p ≤0.001). Independent predictors of MACE were low GFR and a 2 stent strategy. Independent predictors of ST were DAPT duration <3 months and the use of a 2-stent strategy. In conclusion, even stents with very thin strut when implanted in real-life ULM or coronary bifurcation patients discharged with short DAPT have a relevant risk of ST, which remains high although not significant after DAPT cessation.