CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Coronary artery imaging with intravascular high-frequency ultrasound Short-Term Progression of Multiterritorial Subclinical Atherosclerosis Intravascular Ultrasound Assessment of In-Stent Restenosis in Saphenous Vein Grafts Intravascular Ultrasound Guidance Is Associated With Better Outcome in Patients Undergoing Unprotected Left Main Coronary Artery Stenting Compared With Angiography Guidance Alone Metformin Lowers Body Weight But Fails to Increase Insulin Sensitivity in Chronic Heart Failure Patients without Diabetes: a Randomized, Double-Blind, Placebo-Controlled Study Usefulness of intravascular ultrasound guidance in percutaneous coronary intervention with second-generation drug-eluting stents for chronic total occlusions (from the Multicenter Korean-Chronic Total Occlusion Registry) Relationship Between Hospital Surgical Aortic Valve Replacement Volume and Transcatheter Aortic Valve Replacement Outcomes Lifestyle Modifications for Preventing and Treating Heart Failure Exercise Intolerance in Patients With Heart Failure: JACC State-of-the-Art Review Prognostic value of coronary artery calcium screening in subjects with and without diabetes

Original ResearchFebruary 2019, Volume 35, Issue 2, pp 239–247

JOURNAL:Int J Cardiovasc Imaging Article Link

Intravascular Ultrasound Guidance Reduces Cardiac Death and Coronary Revascularization in Patients Undergoing Drug-Eluting Stent Implantation: Results From a Meta-Analysis of 9 Randomized Trials and 4724 Patients

XF Gao , ZM Wang, F Wang et al. Keywords: angiography; drug-eluting stents; intravascular ultrasound; meta-analysis; optimal criteria

ABSTRACT


Intravascular ultrasound (IVUS) guidance is not routinely performed in real-word clinical practice partly because the benefit of IVUS guidance is not well established. This updated meta-analysis aims to compare IVUS-guided and angiography-guided drug-eluting stent (DES) implantation, simultaneously stressing the value of an optimal IVUS-defined procedure. Medline, Scopus, Google Scholar, and Cochrane Controlled Trials Registry were searched for the randomized trials comparing IVUS-guided and angiography-guided DES implantation. Nine eligible randomized trials including 4,724 patients were identified. At a mean follow-up of 16.7 months, IVUS guidance was associated with a significant lower risk of major adverse cardiovascular events (MACE) [5.4% vs. 9.0%; relative risks (RR): 0.61, 95% confident interval (CI) 0.49–0.74, p < 0.001], cardiac death (0.6% vs. 1.2%; RR: 0.49, 95% CI 0.26–0.92, p = 0.03), target vessel revascularization (3.5% vs 6.1%; RR: 0.58, 95% CI 0.42–0.80, p = 0.001), target lesion revascularization (3.1% vs. 5.2%; RR: 0.59, 95% CI 0.44–0.80, p = 0.001), and definite/probable stent thrombosis (0.5% vs .1.1%; RR: 0.45, 95% CI 0.23–0.87, p = 0.02) compared with angiography guidance. No significant differences in all cause death and myocardial infarction were noted between the two groups. Subgroup analysis showed that patients who met the optimal criteria had a lower rate of MACE than those with IVUS-defined suboptimal procedure (RR: 0.33, 95% CI 0.06–0.60, p = 0.02). The present meta-analysis with the largest sample size to date demonstrates that IVUS-guided DES implantation significantly reduces cardiac death, coronary revascularization and stent thrombosis, particularly for patients with IVUS-defined optimal procedures compared with angiography guidance.