Comparison of one-year clinical outcomes between intravascular ultrasound-guided versus angiography-guided implantation of drug-eluting stents for left main lesions: a single-center analysis of a 1,016-patient cohort P2Y12 Inhibitor Monotherapy with Clopidogrel Versus Ticagrelor in Patients with Acute Coronary Syndrome Undergoing Percutaneous Coronary Intervention Comparison of plaque characteristics in narrowings with ST-elevation myocardial infarction (STEMI), non-STEMI/unstable angina pectoris and stable coronary artery disease (from the ADAPT-DES IVUS Substudy) Transcatheter Aortic Valve Implantation Represents an Anti-Inflammatory Therapy Via Reduction of Shear Stress-Induced, Piezo-1-Mediated Monocyte Activation Ticagrelor Monotherapy Versus Dual-Antiplatelet Therapy After PCI: An Individual Patient-Level Meta-Analysis Percutaneous Coronary Intervention for Vulnerable Coronary Atherosclerotic Plaque Reduced Leaflet Motion after Transcatheter Aortic-Valve Replacement Association of Reduced Apical Untwisting With Incident HF in Asymptomatic Patients With HF Risk Factors Rivaroxaban Plus Aspirin Versus Aspirin in Relation to Vascular Risk in the COMPASS Trial Early Rhythm-Control Therapy in Patients with Atrial Fibrillation

Clinical TrialVolume 13, Issue 1, 13 January 2020, Pages 62-71

JOURNAL:JACC Cardiovasc Interv. Article Link

Effect of Intravascular Ultrasound–Guided Drug-Eluting Stent Implantation: 5-Year Follow-Up of the IVUS-XPL Randomized Trial

SJ Hong; GS Mintz; IVUS-XPL Investigators et al. Keywords: CAD;DES; IVUS

ABSTRACT


OBJECTIVES - The goal of this study was to evaluate whether the beneficial effect of use of intravascular ultrasound (IVUS) is sustained for long-term follow-up.

BACKGROUND - The use of IVUS promoted favorable 1-year clinical outcome in the IVUS-XPL (Impact of Intravascular Ultrasound Guidance on the Outcomes of Xience Prime Stents in Long Lesions) trial. It is not known, however, whether this effect is sustained for long-term follow-up.

METHODS - The IVUS-XPL trial randomized 1,400 patients with long coronary lesions (implanted stent length 28 mm) to receive IVUS-guided (n = 700) or angiography-guided (n = 700) everolimus-eluting stent implantation. Five-year clinical outcomes were investigated in patients who completed the original trial. The primary outcome was the composite of major adverse cardiac events, including cardiac death, target lesionrelated myocardial infarction, or ischemia-driven target lesion revascularization at 5 years, analyzed by intention-to-treat.

RESULTS - Five-year follow-up was completed in 1,183 patients (85%). Major adverse cardiac events at 5 years occurred in 36 patients (5.6%) receiving IVUS guidance and in 70 patients (10.7%) receiving angiographic guidance (hazard ratio: 0.50; 95% confidence interval: 0.34 to 0.75; p = 0.001). The difference was driven mainly by a lower risk for target lesion revascularization (31 [4.8%] vs. 55 [8.4%]; hazard ratio: 0.54; 95% confidence interval: 0.33 to 0.89; p = 0.007). By landmark analysis, major adverse cardiac events between 1 and 5 years occurred in 17 patients (2.8%) receiving IVUS guidance and in 31 patients (5.2%) receiving angiographic guidance (hazard ratio: 0.53; 95% confidence interval: 0.29 to 0.95; p = 0.031).

CONCLUSIONS - Compared with angiography-guided stent implantation, IVUS-guided stent implantation resulted in a significantly lower rate of major adverse cardiac events up to 5 years. Sustained 5-year clinical benefits resulted from both within 1 year and from 1 to 5 years post-implantation. (Impact of Intravascular Ultrasound Guidance on the Outcomes of Xience Prime Stents in Long Lesions [IVUS-XPL Study]: Retrospective and Prospective Follow-Up Study; NCT03866486)