CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

An open-Label, 2 × 2 factorial, randomized controlled trial to evaluate the safety of apixaban vs. vitamin K antagonist and aspirin vs. placebo in patients with atrial fibrillation and acute coronary syndrome and/or percutaneous coronary intervention: Rationale and design of the AUGUSTUS trial Management of Patients With NSTE-ACS: A Comparison of the Recent AHA/ACC and ESC Guidelines Coronary flow velocity reserve predicts adverse prognosis in women with angina and noobstructive coronary artery disease: resultsfrom the iPOWER study When high‐volume PCI operators in high‐volume hospitals move to lower volume hospitals—Do they still maintain high volume and quality of outcomes? Coronary Artery Calcium Is Associated with Left Ventricular Diastolic Function Independent of Myocardial Ischemia Effect of Aspirin on All-Cause Mortality in the Healthy Elderly 2017 ACC/AHA/AAPA/ABC/ACPM/AGS/APhA /ASH/ ASPC/NMA/PCNA Guideline for the Prevention, Detection, Evaluation, and Management of High Blood Pressure in Adults: Executive Summary : A Report of the American College of Cardiology/American Heart Association Task Force on Clinical Practice Guidelines Impact of Coronary Lesion Complexity in Percutaneous Coronary Intervention: One-Year Outcomes From the Large, Multicentre e-Ultimaster Registry Drug-Coated Balloon Treatment for Femoropopliteal Artery Disease: The IN.PACT Global Study De Novo In-Stent Restenosis Imaging Cohort Genetic dysregulation of endothelin-1 is implicated in coronary microvascular dysfunction

Clinical TrialVolume 13, Issue 1, 13 January 2020, Pages 62-71

JOURNAL:JACC Cardiovasc Interv. Article Link

Effect of Intravascular Ultrasound–Guided Drug-Eluting Stent Implantation: 5-Year Follow-Up of the IVUS-XPL Randomized Trial

SJ Hong; GS Mintz; IVUS-XPL Investigators et al. Keywords: CAD;DES; IVUS

ABSTRACT


OBJECTIVES - The goal of this study was to evaluate whether the beneficial effect of use of intravascular ultrasound (IVUS) is sustained for long-term follow-up.

BACKGROUND - The use of IVUS promoted favorable 1-year clinical outcome in the IVUS-XPL (Impact of Intravascular Ultrasound Guidance on the Outcomes of Xience Prime Stents in Long Lesions) trial. It is not known, however, whether this effect is sustained for long-term follow-up.

METHODS - The IVUS-XPL trial randomized 1,400 patients with long coronary lesions (implanted stent length 28 mm) to receive IVUS-guided (n = 700) or angiography-guided (n = 700) everolimus-eluting stent implantation. Five-year clinical outcomes were investigated in patients who completed the original trial. The primary outcome was the composite of major adverse cardiac events, including cardiac death, target lesionrelated myocardial infarction, or ischemia-driven target lesion revascularization at 5 years, analyzed by intention-to-treat.

RESULTS - Five-year follow-up was completed in 1,183 patients (85%). Major adverse cardiac events at 5 years occurred in 36 patients (5.6%) receiving IVUS guidance and in 70 patients (10.7%) receiving angiographic guidance (hazard ratio: 0.50; 95% confidence interval: 0.34 to 0.75; p = 0.001). The difference was driven mainly by a lower risk for target lesion revascularization (31 [4.8%] vs. 55 [8.4%]; hazard ratio: 0.54; 95% confidence interval: 0.33 to 0.89; p = 0.007). By landmark analysis, major adverse cardiac events between 1 and 5 years occurred in 17 patients (2.8%) receiving IVUS guidance and in 31 patients (5.2%) receiving angiographic guidance (hazard ratio: 0.53; 95% confidence interval: 0.29 to 0.95; p = 0.031).

CONCLUSIONS - Compared with angiography-guided stent implantation, IVUS-guided stent implantation resulted in a significantly lower rate of major adverse cardiac events up to 5 years. Sustained 5-year clinical benefits resulted from both within 1 year and from 1 to 5 years post-implantation. (Impact of Intravascular Ultrasound Guidance on the Outcomes of Xience Prime Stents in Long Lesions [IVUS-XPL Study]: Retrospective and Prospective Follow-Up Study; NCT03866486)