CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

PCI and CABG for Treating Stable Coronary Artery Disease Radial Versus Femoral Access for Rotational Atherectomy: A UK Observational Study of 8622 Patients Association of CYP2C19 Loss-of-Function Alleles with Major Adverse Cardiovascular Events of Clopidogrel in Stable Coronary Artery Disease Patients Undergoing Percutaneous Coronary Intervention: Meta-analysis Level of Scientific Evidence Underlying the Current American College of Cardiology/American Heart Association Clinical Practice Guidelines Contrast-Associated Acute Kidney Injury and Serious Adverse Outcomes Following Angiography Utilization and programming of an automatic MRI recognition feature for cardiac rhythm management devices Left Ventricular Assist Devices: Synergistic Model Between Technology and Medicine Comparison of Heart Team vs Interventional Cardiologist Recommendations for the Treatment of Patients With Multivessel Coronary Artery Disease In-Hospital Costs and Costs of Complications of Chronic Total Occlusion Angioplasty Insights From the OPEN-CTO Registry The Year in Cardiovascular Medicine 2020: Coronary Intervention

Clinical TrialVolume 13, Issue 1, 13 January 2020, Pages 62-71

JOURNAL:JACC Cardiovasc Interv. Article Link

Effect of Intravascular Ultrasound–Guided Drug-Eluting Stent Implantation: 5-Year Follow-Up of the IVUS-XPL Randomized Trial

SJ Hong; GS Mintz; IVUS-XPL Investigators et al. Keywords: CAD;DES; IVUS

ABSTRACT


OBJECTIVES - The goal of this study was to evaluate whether the beneficial effect of use of intravascular ultrasound (IVUS) is sustained for long-term follow-up.

BACKGROUND - The use of IVUS promoted favorable 1-year clinical outcome in the IVUS-XPL (Impact of Intravascular Ultrasound Guidance on the Outcomes of Xience Prime Stents in Long Lesions) trial. It is not known, however, whether this effect is sustained for long-term follow-up.

METHODS - The IVUS-XPL trial randomized 1,400 patients with long coronary lesions (implanted stent length 28 mm) to receive IVUS-guided (n = 700) or angiography-guided (n = 700) everolimus-eluting stent implantation. Five-year clinical outcomes were investigated in patients who completed the original trial. The primary outcome was the composite of major adverse cardiac events, including cardiac death, target lesionrelated myocardial infarction, or ischemia-driven target lesion revascularization at 5 years, analyzed by intention-to-treat.

RESULTS - Five-year follow-up was completed in 1,183 patients (85%). Major adverse cardiac events at 5 years occurred in 36 patients (5.6%) receiving IVUS guidance and in 70 patients (10.7%) receiving angiographic guidance (hazard ratio: 0.50; 95% confidence interval: 0.34 to 0.75; p = 0.001). The difference was driven mainly by a lower risk for target lesion revascularization (31 [4.8%] vs. 55 [8.4%]; hazard ratio: 0.54; 95% confidence interval: 0.33 to 0.89; p = 0.007). By landmark analysis, major adverse cardiac events between 1 and 5 years occurred in 17 patients (2.8%) receiving IVUS guidance and in 31 patients (5.2%) receiving angiographic guidance (hazard ratio: 0.53; 95% confidence interval: 0.29 to 0.95; p = 0.031).

CONCLUSIONS - Compared with angiography-guided stent implantation, IVUS-guided stent implantation resulted in a significantly lower rate of major adverse cardiac events up to 5 years. Sustained 5-year clinical benefits resulted from both within 1 year and from 1 to 5 years post-implantation. (Impact of Intravascular Ultrasound Guidance on the Outcomes of Xience Prime Stents in Long Lesions [IVUS-XPL Study]: Retrospective and Prospective Follow-Up Study; NCT03866486)