Individual Lesion-Level Meta-Analysis Comparing Various Doses of Intracoronary Bolus Injection of Adenosine With Intravenous Administration of Adenosine for Fractional Flow Reserve Assessment Optimal threshold of postintervention minimum stent area to predict in-stent restenosis in small coronary arteries: An optical coherence tomography analysis Optical Coherence Tomography-Guided Percutaneous Coronary Intervention in ST-Segment-Elevation Myocardial Infarction: A Prospective Propensity-Matched Cohort of the Thrombectomy Versus Percutaneous Coronary Intervention Alone Trial Rotational Atherectomy in acute STEMI with heavily calcified culprit lesion is a rule breaking solution Difference in basic concept of coronary bifurcation intervention between Korea and Japan. Insight from questionnaire in experts of Korean and Japanese bifurcation clubs Long-term clinical outcome after fractional flow reserve-guided treatment in patients with angiographically equivocal left main coronary artery stenosis Sildenafil added to pirfenidone in patients with advanced idiopathic pulmonary fibrosis and risk of pulmonary hypertension: A Phase IIb, randomised, double-blind, placebo-controlled study - Rationale and study design A sirolimus-eluting bioabsorbable polymer-coated stent (MiStent) versus an everolimus-eluting durable polymer stent (Xience) after percutaneous coronary intervention (DESSOLVE III): a randomised, single-blind, multicentre, non-inferiority, phase 3 trial Levosimendan Improves Hemodynamics and Exercise Tolerance in PH-HFpEF: Results of the Randomized Placebo-Controlled HELP Trial Exercise unmasks distinct pathophysiologic features in heart failure with preserved ejection fraction and pulmonary vascular disease

Clinical TrialVolume 13, Issue 1, 13 January 2020, Pages 62-71

JOURNAL:JACC Cardiovasc Interv. Article Link

Effect of Intravascular Ultrasound–Guided Drug-Eluting Stent Implantation: 5-Year Follow-Up of the IVUS-XPL Randomized Trial

SJ Hong; GS Mintz; IVUS-XPL Investigators et al. Keywords: CAD;DES; IVUS

ABSTRACT


OBJECTIVES - The goal of this study was to evaluate whether the beneficial effect of use of intravascular ultrasound (IVUS) is sustained for long-term follow-up.

BACKGROUND - The use of IVUS promoted favorable 1-year clinical outcome in the IVUS-XPL (Impact of Intravascular Ultrasound Guidance on the Outcomes of Xience Prime Stents in Long Lesions) trial. It is not known, however, whether this effect is sustained for long-term follow-up.

METHODS - The IVUS-XPL trial randomized 1,400 patients with long coronary lesions (implanted stent length 28 mm) to receive IVUS-guided (n = 700) or angiography-guided (n = 700) everolimus-eluting stent implantation. Five-year clinical outcomes were investigated in patients who completed the original trial. The primary outcome was the composite of major adverse cardiac events, including cardiac death, target lesionrelated myocardial infarction, or ischemia-driven target lesion revascularization at 5 years, analyzed by intention-to-treat.

RESULTS - Five-year follow-up was completed in 1,183 patients (85%). Major adverse cardiac events at 5 years occurred in 36 patients (5.6%) receiving IVUS guidance and in 70 patients (10.7%) receiving angiographic guidance (hazard ratio: 0.50; 95% confidence interval: 0.34 to 0.75; p = 0.001). The difference was driven mainly by a lower risk for target lesion revascularization (31 [4.8%] vs. 55 [8.4%]; hazard ratio: 0.54; 95% confidence interval: 0.33 to 0.89; p = 0.007). By landmark analysis, major adverse cardiac events between 1 and 5 years occurred in 17 patients (2.8%) receiving IVUS guidance and in 31 patients (5.2%) receiving angiographic guidance (hazard ratio: 0.53; 95% confidence interval: 0.29 to 0.95; p = 0.031).

CONCLUSIONS - Compared with angiography-guided stent implantation, IVUS-guided stent implantation resulted in a significantly lower rate of major adverse cardiac events up to 5 years. Sustained 5-year clinical benefits resulted from both within 1 year and from 1 to 5 years post-implantation. (Impact of Intravascular Ultrasound Guidance on the Outcomes of Xience Prime Stents in Long Lesions [IVUS-XPL Study]: Retrospective and Prospective Follow-Up Study; NCT03866486)