CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Can We Use the Intrinsic Left Ventricular Delay (QLV) to Optimize the Pacing Configuration for Cardiac Resynchronization Therapy With a Quadripolar Left Ventricular Lead? Prognostic Significance of Complex Ventricular Arrhythmias Complicating ST-Segment Elevation Myocardial Infarction Left Main Revascularization in 2017 Coronary Artery Bypass Grafting or Percutaneous Coronary Intervention? Relation between door-to-balloon times and mortality after primary percutaneous coronary intervention over time: a retrospective study Respiratory syncytial virus infection and risk of acute myocardial infarction Improvement of Clinical Outcome in Patients With ST-Elevation Myocardial Infarction Between 1999 And 2016 in China : The Prospective, Multicenter Registry MOODY Study Patterns and associations between DAPT cessation and 2-year clinical outcomes in left main/proximal LAD versus other PCI: Results from the Patterns of Non-Adherence to Dual Antiplatelet Therapy in Stented Patients (PARIS) registry Comparison of double kissing crush versus Culotte stenting for unprotected distal left main bifurcation lesions: results from a multicenter, randomized, prospective DKCRUSH-III study In Vivo Calcium Detection by Comparing Optical Coherence Tomography, Intravascular Ultrasound, and Angiography Recurrent Cardiovascular Events in Survivors of Myocardial Infarction with St-Segment Elevation (From the AMI-QUEBEC Study)

Clinical TrialVolume 13, Issue 1, 13 January 2020, Pages 62-71

JOURNAL:JACC Cardiovasc Interv. Article Link

Effect of Intravascular Ultrasound–Guided Drug-Eluting Stent Implantation: 5-Year Follow-Up of the IVUS-XPL Randomized Trial

SJ Hong; GS Mintz; IVUS-XPL Investigators et al. Keywords: CAD;DES; IVUS

ABSTRACT


OBJECTIVES - The goal of this study was to evaluate whether the beneficial effect of use of intravascular ultrasound (IVUS) is sustained for long-term follow-up.

BACKGROUND - The use of IVUS promoted favorable 1-year clinical outcome in the IVUS-XPL (Impact of Intravascular Ultrasound Guidance on the Outcomes of Xience Prime Stents in Long Lesions) trial. It is not known, however, whether this effect is sustained for long-term follow-up.

METHODS - The IVUS-XPL trial randomized 1,400 patients with long coronary lesions (implanted stent length 28 mm) to receive IVUS-guided (n = 700) or angiography-guided (n = 700) everolimus-eluting stent implantation. Five-year clinical outcomes were investigated in patients who completed the original trial. The primary outcome was the composite of major adverse cardiac events, including cardiac death, target lesionrelated myocardial infarction, or ischemia-driven target lesion revascularization at 5 years, analyzed by intention-to-treat.

RESULTS - Five-year follow-up was completed in 1,183 patients (85%). Major adverse cardiac events at 5 years occurred in 36 patients (5.6%) receiving IVUS guidance and in 70 patients (10.7%) receiving angiographic guidance (hazard ratio: 0.50; 95% confidence interval: 0.34 to 0.75; p = 0.001). The difference was driven mainly by a lower risk for target lesion revascularization (31 [4.8%] vs. 55 [8.4%]; hazard ratio: 0.54; 95% confidence interval: 0.33 to 0.89; p = 0.007). By landmark analysis, major adverse cardiac events between 1 and 5 years occurred in 17 patients (2.8%) receiving IVUS guidance and in 31 patients (5.2%) receiving angiographic guidance (hazard ratio: 0.53; 95% confidence interval: 0.29 to 0.95; p = 0.031).

CONCLUSIONS - Compared with angiography-guided stent implantation, IVUS-guided stent implantation resulted in a significantly lower rate of major adverse cardiac events up to 5 years. Sustained 5-year clinical benefits resulted from both within 1 year and from 1 to 5 years post-implantation. (Impact of Intravascular Ultrasound Guidance on the Outcomes of Xience Prime Stents in Long Lesions [IVUS-XPL Study]: Retrospective and Prospective Follow-Up Study; NCT03866486)