荐读文献

Intravascular ultrasound-guided percutaneous coronary intervention improves the clinical outcome in patients undergoing multiple overlapping drug-eluting stents implantation Ambulatory Electrocardiogram Monitoring in Patients Undergoing Transcatheter Aortic Valve Replacement: JACC State-of-the-Art Review Impact of coronary anatomy and stenting technique on long-term outcome after drug-eluting stent implantation for unprotected left main coronary artery disease In vitro flow and optical coherence tomography comparison of two bailout techniques after failed provisional stenting for bifurcation percutaneous coronary interventions Differences between the left main and other bifurcations Association of Sustained Blood Pressure Control with Multimorbidity Progression Among Older Adults Leaflet immobility and thrombosis in transcatheter aortic valve replacement Pulmonary Artery Denervation Attenuates Pulmonary Arterial Remodeling in Dogs With Pulmonary Arterial Hypertension Induced by Dehydrogenized Monocrotaline Rationale and design of the comparison between a P2Y12 inhibitor monotherapy versus dual antiplatelet therapy in patients undergoing implantation of coronary drug-eluting stents (SMART-CHOICE): A prospective multicenter randomized trial Stent underexpansion and residual reference segment stenosis are related to stent thrombosis after sirolimus-eluting stent implantation: an intravascular ultrasound study

Clinical TrialJanuary 9, 2020

JOURNAL:N Engl J Med. Article Link

Reduced Leaflet Motion after Transcatheter Aortic-Valve Replacement

OD Backer, GD Dangas, the GALILEO-4D Investigators et al. Keywords: leaflet thrombosis substudy; rivaroxaban vs clopidogrel; post TAVR

ABSTRACT


BACKGROUND - Subclinical leaflet thickening and reduced leaflet motion of bioprosthetic aortic valves have been documented by four-dimensional computed tomography (CT). Whether anticoagulation can reduce these phenomena after transcatheter aortic-valve replacement (TAVR) is not known.

 

METHODS - In a substudy of a large randomized trial, we randomly assigned patients who had undergone successful TAVR and who did not have an indication for long-term anticoagulation to a rivaroxaban-based antithrombotic strategy (rivaroxaban [10 mg] plus aspirin [75 to 100 mg] once daily) or an antiplatelet-based strategy (clopidogrel [75 mg] plus aspirin [75 to 100 mg] once daily). Patients underwent evaluation by four-dimensional CT at a mean (±SD) of 90±15 days after randomization. The primary end point was the percentage of patients with at least one prosthetic valve leaflet with grade 3 or higher motion reduction (i.e., involving >50% of the leaflet). Leaflet thickening was also assessed.

 

RESULTS - A total of 231 patients were enrolled. At least one prosthetic valve leaflet with grade 3 or higher motion reduction was found in 2 of 97 patients (2.1%) who had scans that could be evaluated in the rivaroxaban group, as compared with 11 of 101 (10.9%) in the antiplatelet group (difference, 8.8 percentage points; 95% confidence interval [CI], 16.5 to 1.9; P=0.01). Thickening of at least one leaflet was observed in 12 of 97 patients (12.4%) in the rivaroxaban group and in 33 of 102 (32.4%) in the antiplatelet group (difference, 20.0 percentage points; 95% CI, 30.9 to 8.5). In the main trial, the risk of death or thromboembolic events and the risk of life-threatening, disabling, or major bleeding were higher with rivaroxaban (hazard ratios of 1.35 and 1.50, respectively).

 

CONCLUSIONS - In a substudy of a trial involving patients without an indication for long-term anticoagulation who had undergone successful TAVR, a rivaroxaban-based antithrombotic strategy was more effective than an antiplatelet-based strategy in preventing subclinical leaflet-motion abnormalities. However, in the main trial, the rivaroxaban-based strategy was associated with a higher risk of death or thromboembolic complications and a higher risk of bleeding than the antiplatelet-based strategy. (Funded by Bayer; GALILEO-4D ClinicalTrials.gov number, NCT02833948.)