CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

A Fully Magnetically Levitated Left Ventricular Assist Device — Final Report Circadian Cadence and NR1D1 Tune Cardiovascular Disease Diagnosis of Nonischemic Stage B Heart Failure in Type 2 Diabetes Mellitus: Optimal Parameters for Prediction of Heart Failure The spectrum of heart failure: value of left ventricular ejection fraction and its moving trajectories Outcomes After Left Main Percutaneous Coronary Intervention Versus Coronary Artery Bypass Grafting According to Lesion Site Results From the EXCEL Trial Vaccination Trends in Patients With Heart Failure - Insights From Get With The Guidelines–Heart Failure Effects of Dapagliflozin on Symptoms, Function and Quality of Life in Patients with Heart Failure and Reduced Ejection Fraction: Results from the DAPA-HF Trial Rationale and design of the comParIson Of sacubitril/valsartaN versus Enalapril on Effect on nt-pRo-bnp in patients stabilized from an acute Heart Failure episode (PIONEER-HF) trial Intravascular ultrasound guidance to minimize the use of iodine contrast in percutaneous coronary intervention: the MOZART (Minimizing cOntrast utiliZation With IVUS Guidance in coRonary angioplasTy) randomized controlled trial Long-term survival in patients undergoing percutaneous interventions with or without intracoronary pressure wire guidance or intracoronary ultrasonographic imaging: a large cohort study

Clinical TrialJanuary 29, 2020

JOURNAL:N Engl J Med. Article Link

Five-Year Outcomes of Transcatheter or Surgical Aortic-Valve Replacement

RR Makkar, VH Thourani, the PARTNER 2 Investigators. Keywords: intermediate-risk patients; TAVR; SAVR

ABSTRACT


BACKGROUND - There are scant data on long-term clinical outcomes and bioprosthetic-valve function after transcatheter aortic-valve replacement (TAVR) as compared with surgical aortic-valve replacement in patients with severe aortic stenosis and intermediate surgical risk.

 

METHODS - We enrolled 2032 intermediate-risk patients with severe, symptomatic aortic stenosis at 57 centers. Patients were stratified according to intended transfemoral or transthoracic access (76.3% and 23.7%, respectively) and were randomly assigned to undergo either TAVR or surgical replacement. Clinical, echocardiographic, and health-status outcomes were followed for 5 years. The primary end point was death from any cause or disabling stroke.

 

RESULTS - At 5 years, there was no significant difference in the incidence of death from any cause or disabling stroke between the TAVR group and the surgery group (47.9% and 43.4%, respectively; hazard ratio, 1.09; 95% confidence interval [CI], 0.95 to 1.25; P=0.21). Results were similar for the transfemoral-access cohort (44.5% and 42.0%, respectively; hazard ratio, 1.02; 95% CI, 0.87 to 1.20), but the incidence of death or disabling stroke was higher after TAVR than after surgery in the transthoracic-access cohort (59.3% vs. 48.3%; hazard ratio, 1.32; 95% CI, 1.02 to 1.71). At 5 years, more patients in the TAVR group than in the surgery group had at least mild paravalvular aortic regurgitation (33.3% vs. 6.3%). Repeat hospitalizations were more frequent after TAVR than after surgery (33.3% vs. 25.2%), as were aortic-valve reinterventions (3.2% vs. 0.8%). Improvement in health status at 5 years was similar for TAVR and surgery.

 

CONCLUSIONS - Among patients with aortic stenosis who were at intermediate surgical risk, there was no significant difference in the incidence of death or disabling stroke at 5 years after TAVR as compared with surgical aortic-valve replacement. (Funded by Edwards Lifesciences; PARTNER 2 ClinicalTrials.gov number, NCT01314313. )