CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Potential Candidates for Transcatheter Tricuspid Valve Intervention After Transcatheter Aortic Valve Replacement: Predictors and Prognosis Detection of Device-Related Thrombosis Following Left Atrial Appendage Occlusion A Comparison Between Cardiac Computed Tomography and Transesophageal Echocardiography​: A Comparison Between Cardiac Computed Tomography and Transesophageal Echocardiography Frailty and Clinical Outcomes of Direct Oral Anticoagulants Versus Warfarin in Older Adults With Atrial Fibrillation: A Cohort Study Gut microbiota dysbiosis promotes age-related atrial fibrillation by lipopolysaccharide and glucose-induced activation of NLRP3-inflammasome Left Atrial Appendage Occlusion during Cardiac Surgery to Prevent Stroke Left Atrial Appendage Closure versus Non-Warfarin Oral Anticoagulation in Atrial Fibrillation: 4-Year Outcomes of PRAGUE-17 Patent Foramen Ovale Attributable Cryptogenic Embolism With Thrombophilia Has Higher Risk for Recurrence and Responds to Closure Stretch-induced sarcoplasmic reticulum calcium leak is causatively associated with atrial fibrillation in pressure-overloaded hearts 3-Year Outcomes After 2-Stent With Provisional Stenting for Complex Bifurcation Lesions Defined by DEFINITION Criteria TAVI Represents an Anti-Inflammatory Therapy via Reduction of Shear Stress Induced, Piezo-1-Mediated Monocyte Activation

Original Research

JOURNAL:ACC Article Link

Tricuspid Clip in Tricuspid Regurgitation

Gilbert Hin-Lung Tang, MD, MSC, MBA, FACC

Pre-reading

Severe tricuspid regurgitation (TR), whether symptomatic or asymptomatic, is predictive of poor survival if left untreated. Medical therapy, consisting mostly of diuretics, is of limited efficacy. Clinical sequelae, including right heart dysfunction, peripheral edema, and liver congestion, confer a poor quality of life and poor prognosis. Surgical tricuspid repair and replacement have significant mortality and morbidity risks due to patient comorbidities and poor right heart function.

Transcatheter tricuspid valve repair is an emerging alternative to medical therapy and surgery to manage patients with symptomatic severe TR. Several technologies are currently in clinical trials, including edge-to-edge repair, annuloplasty repair, and de novo replacement (Figure 1). The MitraClip device (Abbott Structural Heart; Santa Clara, CA) has been used to repair the tricuspid valve in an off-label manner in over 1,000 cases worldwide with excellent safety and good efficacy, as evidenced by multicenter retrospective studies and the TriValve Registry. The TRILUMINATE (Evaluation of Treatment With Abbott Transcatheter Clip Repair System in Patients With Moderate or Greater Tricuspid Regurgitation) global feasibility study, consisting of sites from the European Union and United States, evaluated transcatheter tricuspid valve repair using the TriClip system (Abbott Structural Heart; Santa Clara, CA). The 1-year outcomes, presented at the 2019 PCR London Valves Annual Meeting, showed excellent safety and efficacy of the TriClip system in terms of TR reduction, low mortality, improvement in quality of life, and right atrial and ventricular modeling (Figures 2-3).1


Figure 1: Transcatheter Tricuspid Therapy Landscape


Figure 2


Figure 3


Imaging the tricuspid valve can be challenging. Transesophageal echocardiography (TEE) is the primary modality used to optimize leaflet grasping and assessment of insertion (Figure 4). Intracardiac echocardiography (ICE) can be a valuable complementary imaging tool to confirm leaflet insertion (Figure 5).2 The TRILUMINATE Pivotal Trial is currently ongoing, randomizing patients with symptomatic severe TR to medical therapy or TriClip or utilizing TriClip as a treatment arm if the TR can be reduced by only one grade in severity.

Figure 4


Figure 5



References

  1. Nickenig G, on behalf of the TRILUMINATE investigators. Percutaneous edge-to-edge repair for tricuspid regurgitation: Initial 1-year outcomes from the TRILUMINATE clinical trial. Presented at PCR London Valves 2019; November 18, 2019.
  2. Tang GH, Yakubov SJ, Sanchez Soto CE. Four-Dimensional Intracardiac Echocardiography in Transcatheter Tricuspid Valve Repair With the MitraClip System. JACC Cardiovasc Imaging 2020;Jan 9:[Epub ahead of print].