CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Why and How to Measure Aortic Valve Calcification in Patients With Aortic Stenosis Transcatheter Aortic Valve Replacement During Pregnancy Use of IVUS guided coronary stenting with drug eluting stent: a systematic review and meta-analysis of randomized controlled clinical trials and high quality observational studies rhACE2 Therapy Modifies Bleomycin-Induced Pulmonary Hypertension via Rescue of Vascular Remodeling Comparison of plaque characteristics in narrowings with ST-elevation myocardial infarction (STEMI), non-STEMI/unstable angina pectoris and stable coronary artery disease (from the ADAPT-DES IVUS Substudy) Comparison of the Efficacy and Safety Outcomes of Edoxaban in 8040 Women Versus 13 065 Men With Atrial Fibrillation in the ENGAGE AF-TIMI 48 Trial Reduced Apolipoprotein M and Adverse Outcomes Across the Spectrum of Human Heart Failure Comprehensive intravascular ultrasound assessment of stent area and its impact on restenosis and adverse cardiac events in 403 patients with unprotected left main disease The Utility of Rapid Atrial Pacing Immediately Post-TAVR to Predict the Need for Pacemaker Implantation Transcatheter Aortic Valve Implantation Represents an Anti-Inflammatory Therapy Via Reduction of Shear Stress-Induced, Piezo-1-Mediated Monocyte Activation

Review ArticleVolume 75, Issue 9, March 2020

JOURNAL:J Am Coll Cardiol. Article Link

Drug-Coated Balloon for De Novo Coronary Artery Disease: JACC State-of-the-Art Review

C Yerasi, BC Case, BJ Forrestal et al. Keywords: CAD; DCB; drug-eluting balloon; paclitaxel-coated balloon; paclitaxel-eluting balloon; small-vessel disease

ABSTRACT


Percutaneous coronary intervention with a drug-eluting stent is the most common mode of revascularization for coronary artery disease. However, restenosis rates remain high. Non-stent-based local drug delivery by a drug-coated balloon (DCB) has been investigated, as it leaves no metallic mesh. A DCB consists of a semicompliant balloon coated with antiproliferative agents encapsulated in a polymer matrix, which is released into the wall after inflation and contact with the intima. DCB have demonstrated effectiveness in treating in-stent restenosis. Clinical studies using DCB in de novo coronary artery disease have shown mixed results, with a major benefit in small-vessel disease. Differences in study results are not only due to variations in DCB technology but also to disparity in procedural approach, “leave nothing behind” or “combination therapy,” and vessel size. This review focuses on the available evidence from randomized trials and proposes a design for future clinical trials.