CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Closure of Iatrogenic Atrial Septal Defect Following Transcatheter Mitral Valve Repair: The Randomized MITHRAS Trial Italian Society of Interventional Cardiology (GIse) Registry Of Transcatheter Treatment of Mitral Valve RegurgitaTiOn (GIOTTO): Impact of Valve Disease Etiology and Residual Mitral Regurgitation after MitraClip Implantation Percutaneous left atrial appendage occlusion: the Munich consensus document on definitions, endpoints, and data collection requirements for clinical studies Mechanistic Biomarkers Informative of Both Cancer and Cardiovascular Disease: JACC State-of-the-Art Review Venous and Arterial Thromboembolism in Patients With Cancer: JACC: CardioOncology State-of-the-Art Review Cardio-oncology: A Focus on Cardiotoxicity Novel Transcatheter Mitral Valve Prosthesis for Patients With Severe Mitral Annular Calcification The Tricuspid Annular Plane Systolic Excursion to Systolic Pulmonary Artery Pressure Index: Association With All-Cause Mortality in Patients With Moderate or Severe Tricuspid Regurgitation Pathophysiology, diagnosis and new therapeutic approaches for ischemic mitral regurgitation Five-Year Clinical Outcomes After Drug-Eluting Stent Implantation Following Rotational Atherectomy for Heavily Calcified Lesions

Review ArticleVolume 75, Issue 9, March 2020

JOURNAL:J Am Coll Cardiol. Article Link

Drug-Coated Balloon for De Novo Coronary Artery Disease: JACC State-of-the-Art Review

C Yerasi, BC Case, BJ Forrestal et al. Keywords: CAD; DCB; drug-eluting balloon; paclitaxel-coated balloon; paclitaxel-eluting balloon; small-vessel disease

ABSTRACT


Percutaneous coronary intervention with a drug-eluting stent is the most common mode of revascularization for coronary artery disease. However, restenosis rates remain high. Non-stent-based local drug delivery by a drug-coated balloon (DCB) has been investigated, as it leaves no metallic mesh. A DCB consists of a semicompliant balloon coated with antiproliferative agents encapsulated in a polymer matrix, which is released into the wall after inflation and contact with the intima. DCB have demonstrated effectiveness in treating in-stent restenosis. Clinical studies using DCB in de novo coronary artery disease have shown mixed results, with a major benefit in small-vessel disease. Differences in study results are not only due to variations in DCB technology but also to disparity in procedural approach, “leave nothing behind” or “combination therapy,” and vessel size. This review focuses on the available evidence from randomized trials and proposes a design for future clinical trials.