CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Wearable Cardioverter-Defibrillator Therapy for the Prevention of Sudden Cardiac Death A Systematic Review and Meta-Analysis A Randomized Trial of a 1-Hour Troponin T Protocol in Suspected Acute Coronary Syndromes: The Rapid Assessment of Possible ACS In the Emergency Department with High Sensitivity Troponin T (RAPID-TnT) Study Contemporary Management of Cardiogenic Shock: A Scientific Statement From the American Heart Association Current Interventions for the Left Main Bifurcation Fourth Universal Definition of Myocardial Infarction (2018) Transcatheter Aortic-Valve Replacement with a Self-Expanding Valve in Low-Risk Patients Investigating methotrexate toxicity within a randomized double-blinded, placebo-controlled trial: Rationale and design of the Cardiovascular Inflammation Reduction Trial-Adverse Events (CIRT-AE) Study One or two stents for the distal Left Main bifurcation The DK crush V study - The DK crush V study 2017 ESC Guidelines for the management of acute myocardial infarction in patients presenting with ST-segment elevation: The Task Force for the management of acute myocardial infarction in patients presenting with ST-segment elevation of the European Society of Cardiology (ESC) Astro-CHARM, the First 10-year ASCVD Risk Estimator Incorporating Coronary Calcium

Review ArticleVolume 75, Issue 9, March 2020

JOURNAL:J Am Coll Cardiol. Article Link

Drug-Coated Balloon for De Novo Coronary Artery Disease: JACC State-of-the-Art Review

C Yerasi, BC Case, BJ Forrestal et al. Keywords: CAD; DCB; drug-eluting balloon; paclitaxel-coated balloon; paclitaxel-eluting balloon; small-vessel disease

ABSTRACT


Percutaneous coronary intervention with a drug-eluting stent is the most common mode of revascularization for coronary artery disease. However, restenosis rates remain high. Non-stent-based local drug delivery by a drug-coated balloon (DCB) has been investigated, as it leaves no metallic mesh. A DCB consists of a semicompliant balloon coated with antiproliferative agents encapsulated in a polymer matrix, which is released into the wall after inflation and contact with the intima. DCB have demonstrated effectiveness in treating in-stent restenosis. Clinical studies using DCB in de novo coronary artery disease have shown mixed results, with a major benefit in small-vessel disease. Differences in study results are not only due to variations in DCB technology but also to disparity in procedural approach, “leave nothing behind” or “combination therapy,” and vessel size. This review focuses on the available evidence from randomized trials and proposes a design for future clinical trials.