CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Chimney technique in a TAVR-in-TAVR procedure with high risk of left main artery ostium occlusion Long-term outcome of prosthesis-patient mismatch after transcatheter aortic valve replacement Meta-Analysis of Effectiveness and Safety of Transcatheter Aortic Valve Implantation Versus Surgical Aortic Valve Replacement in Low-to-Intermediate Surgical Risk Cohort Usefulness of intravascular ultrasound guidance in percutaneous coronary intervention with second-generation drug-eluting stents for chronic total occlusions (from the Multicenter Korean-Chronic Total Occlusion Registry) Discrepancies in Measurement of the Thoracic Aorta: JACC Review Topic of the Week Relationship Between Hospital Surgical Aortic Valve Replacement Volume and Transcatheter Aortic Valve Replacement Outcomes Pulmonary artery denervation to treat pulmonary arterial hypertension: the single-center, prospective, first-in-man PADN-1 study (first-in-man pulmonary artery denervation for treatment of pulmonary artery hypertension) Intravascular Ultrasound Assessment of In-Stent Restenosis in Saphenous Vein Grafts Intravascular ultrasound-guided drug-eluting stent implantation: An updated meta-analysis of randomized control trials and observational studies 2022 AHA/ACC/HFSA Guideline for the Management of Heart Failure: A Report of the American College of Cardiology/American Heart Association Joint Committee on Clinical Practice Guidelines

Original ResearchVolume 13, Issue 6, March 2020

JOURNAL:JACC Cardiovasc Interv. Article Link

Coronary Access After TAVR

T Ochiai, T Chakravarty, SH Yoon et al. Keywords: aortic valve stenosis; coronary angiography; CAD; PCI; TAVR

ABSTRACT


OBJECTIVES - The aim of this study was to assess the incidence of unfavorable coronary access after transcatheter aortic valve replacement (TAVR) using post-implantation computed tomography (CT).

 

BACKGROUND - Real-world data regarding coronary access after TAVR assessed using post-implantation CT are scarce.

 

METHODS - Post-TAVR CT of 66 patients treated with Evolut R or Evolut PRO valves and 345 patients treated with SAPIEN 3 valves were analyzed. The distance from inflow of the transcatheter heart valve (THV) to the coronary ostia and the overlap between THV commissures and the coronary ostia were assessed. Coronary access was defined as unfavorable if the coronary ostium was below the skirt or in front of the THV commissural posts above the skirt in each coronary artery.

 

RESULTS - CT-identified features of unfavorable coronary access were observed in 34.8% (n = 23) for the left coronary artery and 25.8% (n = 17) for the right coronary artery in the Evolut R/Evolut PRO group, while those percentages were 15.7% (n = 54) for the left coronary artery and 8.1% (n = 28) for the right coronary artery in the SAPIEN 3 group. In the Evolut R/Evolut PRO group, 16 coronary engagements were performed after TAVR, while 64 coronary engagements were performed in the SAPIEN 3 group after TAVR. In an engagement-level analysis, the success rates of selective coronary engagement were significantly lower in patients with CT-identified features of unfavorable coronary access compared with those with favorable coronary access in both the Evolut R/Evolut PRO (0.0% vs. 77.8%; p = 0.003) and SAPIEN 3 (33.3% vs. 91.4%; p = 0.003) groups.

 

CONCLUSIONS - Coronary access may be challenging in a significant proportion of patients after TAVR. THVs with low skirt or commissure height and large open cells that are designed to achieve commissure-to-commissure alignment with the native aortic valve may facilitate future coronary access. (Assessment of Transcatheter and Surgical Aortic Bioprosthetic Valve Thrombosis and Its Treatment With Anticoagulation [RESOLVE]; NCT02318342)