Factors associated with pulmonary arterial hypertension (PAH) in systemic sclerosis (SSc) Optical coherence tomography compared with intravascular ultrasound and with angiography to guide coronary stent implantation (ILUMIEN III: OPTIMIZE PCI): a randomised controlled trial Relation of prior statin and anti-hypertensive use to severity of disease among patients hospitalized with COVID-19: Findings from the American Heart Association’s COVID-19 Cardiovascular Disease Registry Intravenous Statin Administration During Myocardial Infarction Compared With Oral Post-Infarct Administration Cardiovascular Aging and Heart Failure: JACC Review Topic of the Week Geometry as a Confounder When Assessing Ventricular Systolic Function: Comparison Between Ejection Fraction and Strain Antiplatelet therapy in patients with myocardial infarction without obstructive coronary artery disease Percutaneous Coronary Intervention for Chronic Total Occlusion—The Michigan Experience: Insights From the BMC2 Registry Efficacy and Safety of Stents in ST-Segment Elevation Myocardial Infarction Transition of Macrophages to Fibroblast-Like Cells in Healing Myocardial Infarction

Original ResearchVolume 13, Issue 6, March 2020

JOURNAL:JACC Cardiovasc Interv. Article Link

Coronary Access After TAVR

T Ochiai, T Chakravarty, SH Yoon et al. Keywords: aortic valve stenosis; coronary angiography; CAD; PCI; TAVR

ABSTRACT


OBJECTIVES - The aim of this study was to assess the incidence of unfavorable coronary access after transcatheter aortic valve replacement (TAVR) using post-implantation computed tomography (CT).

 

BACKGROUND - Real-world data regarding coronary access after TAVR assessed using post-implantation CT are scarce.

 

METHODS - Post-TAVR CT of 66 patients treated with Evolut R or Evolut PRO valves and 345 patients treated with SAPIEN 3 valves were analyzed. The distance from inflow of the transcatheter heart valve (THV) to the coronary ostia and the overlap between THV commissures and the coronary ostia were assessed. Coronary access was defined as unfavorable if the coronary ostium was below the skirt or in front of the THV commissural posts above the skirt in each coronary artery.

 

RESULTS - CT-identified features of unfavorable coronary access were observed in 34.8% (n = 23) for the left coronary artery and 25.8% (n = 17) for the right coronary artery in the Evolut R/Evolut PRO group, while those percentages were 15.7% (n = 54) for the left coronary artery and 8.1% (n = 28) for the right coronary artery in the SAPIEN 3 group. In the Evolut R/Evolut PRO group, 16 coronary engagements were performed after TAVR, while 64 coronary engagements were performed in the SAPIEN 3 group after TAVR. In an engagement-level analysis, the success rates of selective coronary engagement were significantly lower in patients with CT-identified features of unfavorable coronary access compared with those with favorable coronary access in both the Evolut R/Evolut PRO (0.0% vs. 77.8%; p = 0.003) and SAPIEN 3 (33.3% vs. 91.4%; p = 0.003) groups.

 

CONCLUSIONS - Coronary access may be challenging in a significant proportion of patients after TAVR. THVs with low skirt or commissure height and large open cells that are designed to achieve commissure-to-commissure alignment with the native aortic valve may facilitate future coronary access. (Assessment of Transcatheter and Surgical Aortic Bioprosthetic Valve Thrombosis and Its Treatment With Anticoagulation [RESOLVE]; NCT02318342)