Chimney technique in a TAVR-in-TAVR procedure with high risk of left main artery ostium occlusion Long-term outcome of prosthesis-patient mismatch after transcatheter aortic valve replacement Meta-Analysis of Effectiveness and Safety of Transcatheter Aortic Valve Implantation Versus Surgical Aortic Valve Replacement in Low-to-Intermediate Surgical Risk Cohort Usefulness of intravascular ultrasound guidance in percutaneous coronary intervention with second-generation drug-eluting stents for chronic total occlusions (from the Multicenter Korean-Chronic Total Occlusion Registry) Discrepancies in Measurement of the Thoracic Aorta: JACC Review Topic of the Week Relationship Between Hospital Surgical Aortic Valve Replacement Volume and Transcatheter Aortic Valve Replacement Outcomes Pulmonary artery denervation to treat pulmonary arterial hypertension: the single-center, prospective, first-in-man PADN-1 study (first-in-man pulmonary artery denervation for treatment of pulmonary artery hypertension) Intravascular Ultrasound Assessment of In-Stent Restenosis in Saphenous Vein Grafts Intravascular ultrasound-guided drug-eluting stent implantation: An updated meta-analysis of randomized control trials and observational studies 2022 AHA/ACC/HFSA Guideline for the Management of Heart Failure: A Report of the American College of Cardiology/American Heart Association Joint Committee on Clinical Practice Guidelines

Original ResearchVolume 75, Issue 12, March 2020

JOURNAL:J Am Coll Cardiol. Article Link

2-Year Outcomes After Stenting of Lipid-Rich and Nonrich Coronary Plaques

MHwa Yamamoto, A Maehara, GW Stone et al. Keywords: IVUS; lipid-rich plaque; near-infrared spectroscopy; stent

ABSTRACT


BACKGROUND- Autopsy studies suggest that implanting stents in lipid-rich plaque (LRP) may be associated with adverse outcomes.

 

OBJECTIVES- The purpose of this study was to evaluate the association between LRP detected by near-infrared spectroscopy (NIRS) and clinical outcomes in patients with coronary artery disease treated with contemporary drug-eluting stents.

 

METHODS- In this prospective, multicenter registry, NIRS was performed in patients undergoing coronary angiography and possible percutaneous coronary intervention (PCI). Lipid core burden index (LCBI) was calculated as the fraction of pixels with the probability of LRP >0.6 within a region of interest. MaxLCBI4mm was defined as the maximum LCBI within any 4-mm-long segment. Major adverse cardiac events (MACE) included cardiac death, myocardial infarction, definite or probable stent thrombosis, or unplanned revascularization or rehospitalization for progressive angina or unstable angina. Events were subcategorized as culprit (treated) lesionrelated, nonculprit (untreated) lesionrelated, or indeterminate.

 

RESULTS- Among 1,999 patients who were enrolled in the COLOR (Chemometric Observations of Lipid Core Plaques of Interest in Native Coronary Arteries Registry), PCI was performed in 1,621 patients and MACE occurred in 18.0% of patients, of which 8.3% were culprit lesionrelated, 10.7% were nonculprit lesionrelated, and 3.1% were indeterminate during 2-year follow-up. Complications from NIRS imaging occurred in 9 patients (0.45%), which resulted in 1 peri-procedural myocardial infarction and 1 emergent coronary bypass. Pre-PCI NIRS imaging was obtained in 1,189 patients, and the 2-year rate of culprit lesionrelated MACE was not significantly associated with maxLCBI4mm (hazard ratio of maxLCBI4mm per 100: 1.06; 95% confidence interval: 0.96 to 1.17; p = 0.28) after adjusting clinical and procedural factors.

 

CONCLUSIONS- Following PCI with contemporary drug-eluting stents, stent implantation in NIRS-defined LRPs was not associated with increased periprocedural or late adverse outcomes compared with those without significant lipid.