CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

IVUS Guidance for Coronary Revascularization: When to Start, When to Stop? Assessment of coronary atherosclerosis by IVUS and IVUS-based imaging modalities: progression and regression studies, tissue composition and beyond Economic and Quality-of-Life Outcomes of Natriuretic Peptide–Guided Therapy for Heart Failure Intravascular ultrasound predictors for edge restenosis after newer generation drug-eluting stent implantation Fluid Volume Overload and Congestion in Heart Failure: Time to Reconsider Pathophysiology and How Volume Is Assessed Clinical impact of intravascular ultrasound-guided chronic total occlusion intervention with zotarolimus-eluting versus biolimus-eluting stent implantation: randomized study Fractional flow reserve derived from CCTA may have a prognostic role in myocardial bridging A Randomized Study of Distal Filter Protection Versus Conventional Treatment During Percutaneous Coronary Intervention in Patients With Attenuated Plaque Identified by Intravascular Ultrasound Frequency, predictors, and prognosis of ejection fraction improvement in heart failure: an echocardiogram-based registry study The Future of Biomarker-Guided Therapy for Heart Failure After the Guiding Evidence-Based Therapy Using Biomarker Intensified Treatment in Heart Failure (GUIDE-IT) Study

Original ResearchVolume 75, Issue 12, March 2020

JOURNAL:J Am Coll Cardiol. Article Link

2-Year Outcomes After Stenting of Lipid-Rich and Nonrich Coronary Plaques

MHwa Yamamoto, A Maehara, GW Stone et al. Keywords: IVUS; lipid-rich plaque; near-infrared spectroscopy; stent

ABSTRACT


BACKGROUND- Autopsy studies suggest that implanting stents in lipid-rich plaque (LRP) may be associated with adverse outcomes.

 

OBJECTIVES- The purpose of this study was to evaluate the association between LRP detected by near-infrared spectroscopy (NIRS) and clinical outcomes in patients with coronary artery disease treated with contemporary drug-eluting stents.

 

METHODS- In this prospective, multicenter registry, NIRS was performed in patients undergoing coronary angiography and possible percutaneous coronary intervention (PCI). Lipid core burden index (LCBI) was calculated as the fraction of pixels with the probability of LRP >0.6 within a region of interest. MaxLCBI4mm was defined as the maximum LCBI within any 4-mm-long segment. Major adverse cardiac events (MACE) included cardiac death, myocardial infarction, definite or probable stent thrombosis, or unplanned revascularization or rehospitalization for progressive angina or unstable angina. Events were subcategorized as culprit (treated) lesionrelated, nonculprit (untreated) lesionrelated, or indeterminate.

 

RESULTS- Among 1,999 patients who were enrolled in the COLOR (Chemometric Observations of Lipid Core Plaques of Interest in Native Coronary Arteries Registry), PCI was performed in 1,621 patients and MACE occurred in 18.0% of patients, of which 8.3% were culprit lesionrelated, 10.7% were nonculprit lesionrelated, and 3.1% were indeterminate during 2-year follow-up. Complications from NIRS imaging occurred in 9 patients (0.45%), which resulted in 1 peri-procedural myocardial infarction and 1 emergent coronary bypass. Pre-PCI NIRS imaging was obtained in 1,189 patients, and the 2-year rate of culprit lesionrelated MACE was not significantly associated with maxLCBI4mm (hazard ratio of maxLCBI4mm per 100: 1.06; 95% confidence interval: 0.96 to 1.17; p = 0.28) after adjusting clinical and procedural factors.

 

CONCLUSIONS- Following PCI with contemporary drug-eluting stents, stent implantation in NIRS-defined LRPs was not associated with increased periprocedural or late adverse outcomes compared with those without significant lipid.