CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Long-term Cardiopulmonary Consequences of Treatment-Induced Cardiotoxicity in Survivors of ERBB2-Positive Breast Cancer The Tricuspid Annular Plane Systolic Excursion to Systolic Pulmonary Artery Pressure Index: Association With All-Cause Mortality in Patients With Moderate or Severe Tricuspid Regurgitation Outcomes of TTVI in Patients With Pacemaker or Defibrillator Leads: Data From the TriValve Registry Prevalence of potential drug-drug interactions in cancer patients treated with oral anticancer drugs Percutaneous Closure of the Left Atrial Appendage Versus Warfarin Therapy for Prevention of Stroke in Patients With Atrial Fibrillation: A Randomised Non-Inferiority Trial Drug-Coated Balloon Angioplasty Versus Drug-Eluting Stent Implantation in Patients With Coronary Stent Restenosis Rivaroxaban Is Associated With Higher Rates of Gastrointestinal Bleeding Than Other Direct Oral Anticoagulants: A Nationwide Propensity Score–Weighted Study Cardio-Oncology Services: rationale, organization, and implementation: A report from the ESC Cardio-Oncology council Mathematical modelling of endovascular drug delivery: balloons versus stents 2020 ACC Expert Consensus Decision Pathway on Management of Bleeding in Patients on Oral Anticoagulants: A Report of the American College of Cardiology Solution Set Oversight Committee

Original ResearchVolume 13, Issue 7, April 2020

JOURNAL:JACC Article Link

Percutaneous Treatment and Outcomes of Small Coronary Vessels: A SCAAR Report

A Silverio, S Buccheri, G Sarno et al. Keywords: clinical outcomedrug-coated balloonsdrug-eluting stentspercutaneous coronary interventionsmall coronary vessels

ABSTRACT


OBJECTIVES - The aim of this study was to investigate the outcomes of patients with de novo lesions in small coronary vessels undergoing percutaneous coronary intervention (PCI) with drug-coated balloons (DCBs) or newer-generation drug-eluting stents (n-DES).


BACKGROUND - Notwithstanding the available evidence from a few randomized clinical trials and meta-analyses, the best device for PCI in patients with small-vessel coronary artery disease is not yet established.


METHODS - The study included all consecutive patients with de novo lesions in small coronary vessels undergoing PCI in Sweden from April 2009 to July 2017. A small coronary vessel was defined by a device diameter ≤2.5 mm. The primary outcomes were restenosis and definite target lesion thrombosis at 3-year follow-up. The secondary outcomes were the occurrence of all-cause death and myocardial infarction.


RESULTS - The study population included 14,788 patients: 1,154 treated with DCBs and 13,634 with n-DES. Overall, 35,541 PCIs were performed using 2,503 DCBs and 33,038 n-DES. The propensity score–adjusted regression analysis showed a significantly higher risk for restenosis in the DCB group compared with the n-DES group (adjusted hazard ratio [HR]: 2.027; 95% confidence interval [CI]: 1.537 to 2.674). Conversely, no difference in the risk for target lesion thrombosis (adjusted HR: 0.741; 95% CI: 0.412 to 1.331) was detected. The risk for all-cause death (adjusted HR: 1.178; 95% CI: 0.992 to 1.399) and myocardial infarction (adjusted HR: 1.251; 95% CI: 0.960 to 1.629) was comparable between groups.


CONCLUSIONS - Because of the significantly higher risk for restenosis up to 3 years, this research suggests that DCBs are not an equally effective alternative to n-DES for percutaneous treatment of small coronary vessels.