CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Poor Long-Term Survival in Patients With Moderate Aortic Stenosis A Randomized Controlled Trial to Evaluate the Safety and Efficacy of Cardiac Contractility Modulation Lipid-Modifying Agents, From Statins to PCSK9 Inhibitors: JACC Focus Seminar Major Bleeding Rates in Atrial Fibrillation Patients on Single, Dual, or Triple Antithrombotic Therapy Safety and efficacy of a self-expanding versus a balloon-expandable bioprosthesis for transcatheter aortic valve replacement in patients with symptomatic severe aortic stenosis: a randomised non-inferiority trial Effects of Intravascular Ultrasound-Guided Versus Angiography-Guided New-Generation Drug-Eluting Stent Implantation: Meta-Analysis With Individual Patient-Level Data From 2,345 Randomized Patients Aspirin with or without Clopidogrel after Transcatheter Aortic-Valve Implantation 2017 AHA/ACC Focused Update of the 2014 AHA/ACC Guideline for the Management of Patients With Valvular Heart Disease: A Report of the American College of Cardiology/American Heart Association Task Force on Clinical Practice Guidelines Cardiac surgery following transcatheter aortic valve replacement Haemodynamic-guided management of heart failure (GUIDE-HF): a randomised controlled trial

Original ResearchVolume 13, Issue 7, April 2020

JOURNAL:JACC Article Link

Percutaneous Treatment and Outcomes of Small Coronary Vessels: A SCAAR Report

A Silverio, S Buccheri, G Sarno et al. Keywords: clinical outcomedrug-coated balloonsdrug-eluting stentspercutaneous coronary interventionsmall coronary vessels

ABSTRACT


OBJECTIVES - The aim of this study was to investigate the outcomes of patients with de novo lesions in small coronary vessels undergoing percutaneous coronary intervention (PCI) with drug-coated balloons (DCBs) or newer-generation drug-eluting stents (n-DES).


BACKGROUND - Notwithstanding the available evidence from a few randomized clinical trials and meta-analyses, the best device for PCI in patients with small-vessel coronary artery disease is not yet established.


METHODS - The study included all consecutive patients with de novo lesions in small coronary vessels undergoing PCI in Sweden from April 2009 to July 2017. A small coronary vessel was defined by a device diameter ≤2.5 mm. The primary outcomes were restenosis and definite target lesion thrombosis at 3-year follow-up. The secondary outcomes were the occurrence of all-cause death and myocardial infarction.


RESULTS - The study population included 14,788 patients: 1,154 treated with DCBs and 13,634 with n-DES. Overall, 35,541 PCIs were performed using 2,503 DCBs and 33,038 n-DES. The propensity score–adjusted regression analysis showed a significantly higher risk for restenosis in the DCB group compared with the n-DES group (adjusted hazard ratio [HR]: 2.027; 95% confidence interval [CI]: 1.537 to 2.674). Conversely, no difference in the risk for target lesion thrombosis (adjusted HR: 0.741; 95% CI: 0.412 to 1.331) was detected. The risk for all-cause death (adjusted HR: 1.178; 95% CI: 0.992 to 1.399) and myocardial infarction (adjusted HR: 1.251; 95% CI: 0.960 to 1.629) was comparable between groups.


CONCLUSIONS - Because of the significantly higher risk for restenosis up to 3 years, this research suggests that DCBs are not an equally effective alternative to n-DES for percutaneous treatment of small coronary vessels.