Effects of Icosapent Ethyl on Total Ischemic Events: From REDUCE-IT Early Rhythm-Control Therapy in Patients with Atrial Fibrillation Impact of Intravascular Ultrasound on Long-Term Clinical Outcomes in Patients With Acute Myocardial Infarction Impact of post-intervention minimal stent area on 9-month follow-up patency of paclitaxel-eluting stents: an integrated intravascular ultrasound analysis from the TAXUS IV, V, and VI and TAXUS ATLAS Workhorse, Long Lesion, and Direct Stent Trials Diagnostic accuracy of cardiac positron emission tomography versus single photon emission computed tomography for coronary artery disease: a bivariate meta-analysis Osteoarthritis risk is reduced after treatment with ticagrelor compared to clopidogrel: a propensity score matching analysis Meta-Analysis of Comparison of 5-Year Outcomes of Percutaneous Coronary Intervention Versus Coronary Artery Bypass Grafting in Patients With Unprotected Left Main Coronary Artery in the Era of Drug-eluting Stents Valve‐in‐Valve for Degenerated Transcatheter Aortic Valve Replacement Versus Valve‐in‐Valve for Degenerated Surgical Aortic Bioprostheses: A 3‐Center Comparison of Hemodynamic and 1‐Year Outcome Second vs. First generation drug eluting stents in multiple vessel disease and left main stenosis: Two-year follow-up of the observational, prospective, controlled, and multicenter ERACI IV registry Long-term outcomes following mini-crush versus culotte stenting for the treatment of unprotected left main disease: insights from the Milan and New-Tokyo (MITO) registry

Original Research2020 Apr 28.

JOURNAL:Eurointervention. Article Link

Double-Kissing Culotte Technique for Coronary Bifurcation Stenting - Technical evaluation and comparison with conventional double stenting techniques

GG Toth, V Sasi; D Franco et al. Keywords: technique improvement; culotte technique

ABSTRACT

AIMS - To assess, whether Culotte technique could be improved by an additional kissing dilation prior main branch (MB) stenting.

 

METHODS AND RESULTS - Double-kissing (DK) Culotte was compared to Culotte and DK-Crush techniques in bench model (n=24). Results were evaluated for stent apposition, for luminal opening and for flow dynamics.Total procedure duration of DK-Culotte was 18.3±3.4min, significantly lower than for DK-Crush (24.3±5.7min; p=0.015), however similar to Culotte (21.6±5.9min, p=0.104).In DK-Culotte overall rate of moderate (200-500mm) and significant (>500mm) malapposition was 2.1±1.9% and 0.4±0.2%; similar as compared to Culotte (3.7±3.8%, p=0.459 and 1.0±1.0%, p=0.517; respectively), and lower as compared to DK-Crush (8.1±2.5%, p<0.001 and 3.7±5.3%, p=0.002; respectively). Lower malapposition rate of DK-Culotte as compared to DK-Crush was due to less moderate and significant malapposition in proximal MB (0.0±0.0% vs. 14.0±7.6%, p<0.001 and 0.0±0.0% vs. 4.2±9.1%, p=0.026, respectively). Micro computed tomography did not show difference in luminal opening at proximal MB, distal MB or SB. There was no difference either in maximum shear rate or in areas of high shear or recirculation.

 

CONCLUSIONS - Bench tests data suggest that DK approach facilitates Culotte technique. Clinical validity and relevance remains to be confirmed in larger in vivo population.