Echocardiographic Screening for Pulmonary Hypertension in Congenital Heart Disease Management of pulmonary hypertension from left heart disease in candidates for orthotopic heart transplantation Classification and treatment of coronary artery bifurcation lesions: putting the Medina classification to the test One Versus 2-stent Strategy for the Treatment of Bifurcation Lesions in the Context of a Coronary Chronic Total Occlusion: A Multicenter Registry Left ventricular remodelling and changes in functional measurements in patients undergoing transcatheter vs surgical aortic valve replacement: a head-to-head comparison Coronary fractional flow reserve in bifurcation stenoses: what have we learned? Diagnostic accuracy of intracoronary optical coherence tomography-derived fractional flow reserve for assessment of coronary stenosis severity T and small protrusion (TAP) vs double kissing crush technique: Insights from in-vitro models ‘Small bifurcation?’ CT myocardial mass volume measurements change therapeutic strategy in coronary artery disease Therapeutic efficacy of paclitaxel-coated balloon for de novo coronary lesions with diameters larger than 2.8 mm

Original Research2020 Apr 28.

JOURNAL:Eurointervention. Article Link

Double-Kissing Culotte Technique for Coronary Bifurcation Stenting - Technical evaluation and comparison with conventional double stenting techniques

GG Toth, V Sasi; D Franco et al. Keywords: technique improvement; culotte technique

ABSTRACT

AIMS - To assess, whether Culotte technique could be improved by an additional kissing dilation prior main branch (MB) stenting.

 

METHODS AND RESULTS - Double-kissing (DK) Culotte was compared to Culotte and DK-Crush techniques in bench model (n=24). Results were evaluated for stent apposition, for luminal opening and for flow dynamics.Total procedure duration of DK-Culotte was 18.3±3.4min, significantly lower than for DK-Crush (24.3±5.7min; p=0.015), however similar to Culotte (21.6±5.9min, p=0.104).In DK-Culotte overall rate of moderate (200-500mm) and significant (>500mm) malapposition was 2.1±1.9% and 0.4±0.2%; similar as compared to Culotte (3.7±3.8%, p=0.459 and 1.0±1.0%, p=0.517; respectively), and lower as compared to DK-Crush (8.1±2.5%, p<0.001 and 3.7±5.3%, p=0.002; respectively). Lower malapposition rate of DK-Culotte as compared to DK-Crush was due to less moderate and significant malapposition in proximal MB (0.0±0.0% vs. 14.0±7.6%, p<0.001 and 0.0±0.0% vs. 4.2±9.1%, p=0.026, respectively). Micro computed tomography did not show difference in luminal opening at proximal MB, distal MB or SB. There was no difference either in maximum shear rate or in areas of high shear or recirculation.

 

CONCLUSIONS - Bench tests data suggest that DK approach facilitates Culotte technique. Clinical validity and relevance remains to be confirmed in larger in vivo population.