Managing Multivessel Coronary Artery Disease in Patients With ST-Elevation Myocardial Infarction: A Comprehensive Review New technologies for intensive prevention programs after myocardial infarction: rationale and design of the NET-IPP trial The prognostic role of mid-range ejection fraction in ST-segment elevation myocardial infarction Skeletal muscle mitochondrial oxidative phosphorylation function in idiopathic pulmonary arterial hypertension: in vivo and in vitro study Short Duration of DAPT Versus De-Escalation After Percutaneous Coronary Intervention for Acute Coronary Syndromes Sex-Specific Thresholds of High-Sensitivity Troponin in Patients With Suspected Acute Coronary Syndrome 1-Year Outcomes of Patients Undergoing Primary Angioplasty for Myocardial Infarction Treated With Prasugrel Versus Ticagrelor Effect of Lipoprotein (a) Levels on Long-term Cardiovascular Outcomes in Patients with Myocardial Infarction with Nonobstructive Coronary Arteries Off-hour presentation and outcomes in patients with acute myocardial infarction: systematic review and meta-analysis State of the art: duration of dual antiplatelet therapy after percutaneous coronary intervention and coronary stent implantation - past, present and future perspectives.

Original Research2020 Apr 28.

JOURNAL:Eurointervention. Article Link

Double-Kissing Culotte Technique for Coronary Bifurcation Stenting - Technical evaluation and comparison with conventional double stenting techniques

GG Toth, V Sasi; D Franco et al. Keywords: technique improvement; culotte technique

ABSTRACT

AIMS - To assess, whether Culotte technique could be improved by an additional kissing dilation prior main branch (MB) stenting.

 

METHODS AND RESULTS - Double-kissing (DK) Culotte was compared to Culotte and DK-Crush techniques in bench model (n=24). Results were evaluated for stent apposition, for luminal opening and for flow dynamics.Total procedure duration of DK-Culotte was 18.3±3.4min, significantly lower than for DK-Crush (24.3±5.7min; p=0.015), however similar to Culotte (21.6±5.9min, p=0.104).In DK-Culotte overall rate of moderate (200-500mm) and significant (>500mm) malapposition was 2.1±1.9% and 0.4±0.2%; similar as compared to Culotte (3.7±3.8%, p=0.459 and 1.0±1.0%, p=0.517; respectively), and lower as compared to DK-Crush (8.1±2.5%, p<0.001 and 3.7±5.3%, p=0.002; respectively). Lower malapposition rate of DK-Culotte as compared to DK-Crush was due to less moderate and significant malapposition in proximal MB (0.0±0.0% vs. 14.0±7.6%, p<0.001 and 0.0±0.0% vs. 4.2±9.1%, p=0.026, respectively). Micro computed tomography did not show difference in luminal opening at proximal MB, distal MB or SB. There was no difference either in maximum shear rate or in areas of high shear or recirculation.

 

CONCLUSIONS - Bench tests data suggest that DK approach facilitates Culotte technique. Clinical validity and relevance remains to be confirmed in larger in vivo population.