Right ventricular stroke work correlates with outcomes in pediatric pulmonary arterial hypertension State of the Art in Noninvasive Imaging of Ischemic Heart Disease and Coronary Microvascular Dysfunction in Women: Indications, Performance, and Limitations Early Diagnosis of Myocardial Infarction With Point-of-Care High-Sensitivity Cardiac Troponin I Derivation and Validation of a Chronic Total Coronary Occlusion Intervention Procedural Success Score From the 20,000-Patient EuroCTO Registry:The EuroCTO (CASTLE) Score Heart Disease and Stroke Statistics-2019 Update: A Report From the American Heart Association Switching P2Y12-receptor inhibitors in patients with coronary artery disease Atrial Fibrillation Burden: Moving Beyond Atrial Fibrillation as a Binary Entity: A Scientific Statement From the American Heart Association COVID-19 and Thrombotic or Thromboembolic Disease: Implications for Prevention, Antithrombotic Therapy, and Follow-up Randomized comparison of stent strut coverage following angiography- or optical coherence tomography-guided percutaneous coronary intervention Effect of Aspirin on All-Cause Mortality in the Healthy Elderly

Original Research2020 Apr 28.

JOURNAL:Eurointervention. Article Link

Double-Kissing Culotte Technique for Coronary Bifurcation Stenting - Technical evaluation and comparison with conventional double stenting techniques

GG Toth, V Sasi; D Franco et al. Keywords: technique improvement; culotte technique

ABSTRACT

AIMS - To assess, whether Culotte technique could be improved by an additional kissing dilation prior main branch (MB) stenting.

 

METHODS AND RESULTS - Double-kissing (DK) Culotte was compared to Culotte and DK-Crush techniques in bench model (n=24). Results were evaluated for stent apposition, for luminal opening and for flow dynamics.Total procedure duration of DK-Culotte was 18.3±3.4min, significantly lower than for DK-Crush (24.3±5.7min; p=0.015), however similar to Culotte (21.6±5.9min, p=0.104).In DK-Culotte overall rate of moderate (200-500mm) and significant (>500mm) malapposition was 2.1±1.9% and 0.4±0.2%; similar as compared to Culotte (3.7±3.8%, p=0.459 and 1.0±1.0%, p=0.517; respectively), and lower as compared to DK-Crush (8.1±2.5%, p<0.001 and 3.7±5.3%, p=0.002; respectively). Lower malapposition rate of DK-Culotte as compared to DK-Crush was due to less moderate and significant malapposition in proximal MB (0.0±0.0% vs. 14.0±7.6%, p<0.001 and 0.0±0.0% vs. 4.2±9.1%, p=0.026, respectively). Micro computed tomography did not show difference in luminal opening at proximal MB, distal MB or SB. There was no difference either in maximum shear rate or in areas of high shear or recirculation.

 

CONCLUSIONS - Bench tests data suggest that DK approach facilitates Culotte technique. Clinical validity and relevance remains to be confirmed in larger in vivo population.