CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Successful Treatment of Unprotected Left Main Coronary Bifurcation Lesion Using Minimum Contrast Volume with Intravascular Ultrasound Guidance Astro-CHARM, the First 10-year ASCVD Risk Estimator Incorporating Coronary Calcium Improving the Use of Primary Prevention Implantable Cardioverter-Defibrillators Therapy With Validated Patient-Centric Risk Estimates Mortality Following Cardiovascular and Bleeding Events Occurring Beyond 1 Year After Coronary Stenting - A Secondary Analysis of the Dual Antiplatelet Therapy (DAPT) Study Benefit of switching dual antiplatelet therapy after acute coronary syndrome: the TOPIC (timing of platelet inhibition after acute coronary syndrome) randomized study Intravascular ultrasound guidance in drug-eluting stents implantation: a meta-analysis and trial sequential analysis of randomized controlled trials Relationship Between Infarct Size and Outcomes Following Primary PCI: Patient-Level Analysis From 10 Randomized Trials Intracoronary Optical Coherence Tomography 2018: Current Status and Future Directions Intravascular ultrasound-guided percutaneous coronary intervention in left main coronary bifurcation lesions: a review Intra-aortic balloon counterpulsation in acute myocardial infarction complicated by cardiogenic shock (IABP-SHOCK II): final 12 month results of a randomised, open-label trial

Original ResearchVolume 13, Issue 9, May 2020

JOURNAL:JACC: Cardiovascular Interventions Article Link

Transcatheter Aortic Valve Replacement in Low-Risk Patients With Symptomatic Severe Bicuspid Aortic Valve Stenosis

R Waksman, PE Craig, R Torguson et al. Keywords: aortic stenosis; bicuspid aortic valve; low risk; transcatheter aortic valve replacement

ABSTRACT

OBJECTIVES - The aim of this study was to evaluate clinical outcomes and transcatheter heart valve hemodynamic parameters after transcatheter aortic valve replacement (TAVR) in low-risk patients with bicuspid aortic stenosis (AS).

 

BACKGROUND - TAVR is approved for low-risk patients in the United States. However, patients with bicuspid AS were excluded from the randomized cohorts of the pivotal low-risk trials.

 

METHODS - The LRT (Low Risk TAVR) trial was an investigator-initiated, prospective, multicenter study and was the first and only U.S. Food and Drug Administrationapproved investigational device exemption trial to evaluate the feasibility of TAVR with either balloon-expandable or self-expanding valves in low-risk patients with bicuspid AS. The primary endpoint was all-cause mortality at 30 days. Baseline and follow-up echocardiography and computed tomography to detect leaflet thickening were analyzed in an independent core laboratory.

 

RESULTS - Sixty-one low-risk patients with symptomatic, severe AS and bicuspid aortic valves (78.3% Sievers type 1 morphology) underwent TAVR at 6 centers from 2016 to 2019. The mean age was 68.6 years, and 42.6% were men. At 30 days, there was zero mortality and no disabling strokes. The rate of new permanent pacemaker implantation was 13.1%; just 1 patient had a moderate paravalvular leak at 30 days. Hypoattenuated leaflet thickening was observed in 10% of patients at 30 days.

 

CONCLUSIONS - TAVR appears to be safe in patients with bicuspid AS, with short length of hospital stay, zero mortality, and no disabling strokes at 30 days. Subclinical leaflet thrombosis was observed in a minority of patients at 30 days but did not appear to be associated with clinical events.