Outcomes 2 Years After Transcatheter Aortic Valve Replacement in Patients at Low Surgical Risk Relation between baseline plaque features and subsequent coronary artery remodeling determined by optical coherence tomography and intravascular ultrasound Impact of final stent dimensions on long-term results following sirolimus-eluting stent implantation: serial intravascular ultrasound analysis from the sirius trial Online Quantitative Aortographic Assessment of Aortic Regurgitation After TAVR: Results of the OVAL Study Randomized comparison of clinical outcomes between intravascular ultrasound and angiography-guided drug-eluting stent implantation for long coronary artery stenoses Utility of intravascular ultrasound guidance in patients undergoing percutaneous coronary intervention for type C lesions Colchicine Reduces Cardiovascular Events in Chronic Coronary Disease A volumetric intravascular ultrasound comparison of early drug-eluting stent thrombosis versus restenosis Cardiac and Kidney Benefits of Empagliflozin in Heart Failure Across the Spectrum of Kidney Function: Insights From EMPEROR-Reduced The effect of complete percutaneous revascularisation with and without intravascular ultrasound guidance in the drugeluting stent era

Original ResearchVolume 13, Issue 9, May 2020

JOURNAL:JACC: Cardiovascular Interventions Article Link

The Utility of Rapid Atrial Pacing Immediately Post-TAVR to Predict the Need for Pacemaker Implantation

A Krishnaswamy, Y Sammour, A Mangieri et al. Keywords: atrial pacing; electrophysiology study; permanent pacemaker implantation;TAVR

ABSTRACT

OBJECTIVES - The aim of this study was to determine the utility of rapid atrial pacing immediately after transcatheter aortic valve replacement (TAVR) to predict the need for permanent pacemaker implantation (PPI).

 

BACKGROUND - Risk stratification for patients without high-grade atrioventricular block (AVB) after TAVR is imprecise and based on anatomic considerations, electrocardiographic characteristics, and clinical suspicion. A more reliable assessment is necessary to minimize inpatient rhythm monitoring and/or reduce unnecessary PPI.

 

METHODS - Consecutive patients undergoing TAVR at 2 centers were included. After valve implantation in patients without pacemakers who did not have complete heart block or atrial fibrillation, the temporary pacemaker was withdrawn from the right ventricle and placed in the right atrium. Rapid atrial pacing was performed from 70 to 120 beats/min, and patients were assessed for the development of Wenckebach AVB. Patients were then followed for clinical outcomes, including PPI.

 

RESULTS - A total of 284 patients were included. Of these, 130 (45.8%) developed Wenckebach AVB. There was a higher rate of PPI within 30 days of TAVR among the patients who developed Wenckebach AVB (13.1% vs. 1.3%; p < 0.001), with a negative predictive value for PPI in the group without Wenckebach AVB of 98.7%. A greater percentage of patients receiving self-expanding valves required PPI than those receiving a balloon-expandable valves (15.9% vs. 3.7%; p = 0.001), though these rates were still relatively low among patients who did not develop Wenckebach AVB (2.9% and 0.8%).

 

CONCLUSIONS - Atrial pacing post-TAVR is easily performed and can help identify patients who may benefit from extended rhythm monitoring. Patients who did not develop pacing-induced Wenckebach AVB demonstrated an extremely low likelihood of PPI.