Feasibility and efficacy of the ultrashort side branch dedicated balloon in coronary bifurcation stenting Inhibition of Platelet Aggregation After Coronary Stenting in Patients Receiving Oral Anticoagulation 10-Year Outcomes of Stents Versus Coronary Artery Bypass Grafting for Left Main Coronary Artery Disease Bayesian Interpretation of the EXCEL Trial and Other Randomized Clinical Trials of Left Main Coronary Artery Revascularization Drug-eluting stent implantation in patients with acute coronary syndrome - the Activity of Platelets after Inhibition and Cardiovascular Events: Optical Coherence Tomography (APICE OCT) study Intravascular Imaging and 12-Month Mortality After Unprotected Left Main Stem PCI: An Analysis From the British Cardiovascular Intervention Society Database Impact of Percutaneous Revascularization on Exercise Hemodynamics in Patients With Stable Coronary Disease Comprehensive Investigation of Circulating Biomarkers and their Causal Role in Atherosclerosis-related Risk Factors and Clinical Events Left atrial appendage occlusion in atrial fibrillation patients with previous intracranial bleeding: A national multicenter study Efficacy and safety of low-dose colchicine in patients with coronary disease: a systematic review and meta-analysis of randomized trials

Original ResearchVolume 13, Issue 9, May 2020

JOURNAL:JACC: Cardiovascular Interventions Article Link

The Utility of Rapid Atrial Pacing Immediately Post-TAVR to Predict the Need for Pacemaker Implantation

A Krishnaswamy, Y Sammour, A Mangieri et al. Keywords: atrial pacing; electrophysiology study; permanent pacemaker implantation;TAVR

ABSTRACT

OBJECTIVES - The aim of this study was to determine the utility of rapid atrial pacing immediately after transcatheter aortic valve replacement (TAVR) to predict the need for permanent pacemaker implantation (PPI).

 

BACKGROUND - Risk stratification for patients without high-grade atrioventricular block (AVB) after TAVR is imprecise and based on anatomic considerations, electrocardiographic characteristics, and clinical suspicion. A more reliable assessment is necessary to minimize inpatient rhythm monitoring and/or reduce unnecessary PPI.

 

METHODS - Consecutive patients undergoing TAVR at 2 centers were included. After valve implantation in patients without pacemakers who did not have complete heart block or atrial fibrillation, the temporary pacemaker was withdrawn from the right ventricle and placed in the right atrium. Rapid atrial pacing was performed from 70 to 120 beats/min, and patients were assessed for the development of Wenckebach AVB. Patients were then followed for clinical outcomes, including PPI.

 

RESULTS - A total of 284 patients were included. Of these, 130 (45.8%) developed Wenckebach AVB. There was a higher rate of PPI within 30 days of TAVR among the patients who developed Wenckebach AVB (13.1% vs. 1.3%; p < 0.001), with a negative predictive value for PPI in the group without Wenckebach AVB of 98.7%. A greater percentage of patients receiving self-expanding valves required PPI than those receiving a balloon-expandable valves (15.9% vs. 3.7%; p = 0.001), though these rates were still relatively low among patients who did not develop Wenckebach AVB (2.9% and 0.8%).

 