Atherosclerotic plaque with ultrasonic attenuation affects coronary reflow and infarct size in patients with acute coronary syndrome: an intravascular ultrasound study Temporal Trends in Transcatheter Aortic Valve Replacement in France: FRANCE 2 to FRANCE TAVI Impact of intravascular ultrasound on the long-term clinical outcomes in the treatment of coronary ostial lesions When and how to use SGLT2 inhibitors in patients with HFrEF or chronic kidney disease Novel predictor of target vessel revascularization after coronary stent implantation: Intraluminal intensity of blood speckle on intravascular ultrasound The relationship between attenuated plaque identified by intravascular ultrasound and no-reflow after stenting in acute myocardial infarction: the HORIZONS-AMI (Harmonizing Outcomes With Revascularization and Stents in Acute Myocardial Infarction) trial How to diagnose heart failure with preserved ejection fraction: the HFA–PEFF diagnostic algorithm: a consensus recommendation from the Heart Failure Association (HFA) of the European Society of Cardiology (ESC) Heart Failure Outcomes With Volume-Guided Management Sex Differences in Heart Failure With Preserved Ejection Fraction Pathophysiology: A Detailed Invasive Hemodynamic and Echocardiographic Analysis Intravascular Ultrasound to Guide Left Main Stem Intervention: A Sub-Study of the NOBLE Trial

Original ResearchVolume 13, Issue 9, May 2020

JOURNAL:JACC: Cardiovascular Interventions Article Link

The Utility of Rapid Atrial Pacing Immediately Post-TAVR to Predict the Need for Pacemaker Implantation

A Krishnaswamy, Y Sammour, A Mangieri et al. Keywords: atrial pacing; electrophysiology study; permanent pacemaker implantation;TAVR

ABSTRACT

OBJECTIVES - The aim of this study was to determine the utility of rapid atrial pacing immediately after transcatheter aortic valve replacement (TAVR) to predict the need for permanent pacemaker implantation (PPI).

 

BACKGROUND - Risk stratification for patients without high-grade atrioventricular block (AVB) after TAVR is imprecise and based on anatomic considerations, electrocardiographic characteristics, and clinical suspicion. A more reliable assessment is necessary to minimize inpatient rhythm monitoring and/or reduce unnecessary PPI.

 

METHODS - Consecutive patients undergoing TAVR at 2 centers were included. After valve implantation in patients without pacemakers who did not have complete heart block or atrial fibrillation, the temporary pacemaker was withdrawn from the right ventricle and placed in the right atrium. Rapid atrial pacing was performed from 70 to 120 beats/min, and patients were assessed for the development of Wenckebach AVB. Patients were then followed for clinical outcomes, including PPI.

 

RESULTS - A total of 284 patients were included. Of these, 130 (45.8%) developed Wenckebach AVB. There was a higher rate of PPI within 30 days of TAVR among the patients who developed Wenckebach AVB (13.1% vs. 1.3%; p < 0.001), with a negative predictive value for PPI in the group without Wenckebach AVB of 98.7%. A greater percentage of patients receiving self-expanding valves required PPI than those receiving a balloon-expandable valves (15.9% vs. 3.7%; p = 0.001), though these rates were still relatively low among patients who did not develop Wenckebach AVB (2.9% and 0.8%).

 

CONCLUSIONS - Atrial pacing post-TAVR is easily performed and can help identify patients who may benefit from extended rhythm monitoring. Patients who did not develop pacing-induced Wenckebach AVB demonstrated an extremely low likelihood of PPI.