CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Comparison in prevalence, predictors, and clinical outcome of VSR versus FWR after acute myocardial infarction: The prospective, multicenter registry MOODY trial-heart rupture analysis Natural History of Spontaneous Coronary Artery Dissection With Spontaneous Angiographic Healing Cardiac Troponin Composition Characterization after Non ST-Elevation Myocardial Infarction: Relation with Culprit Artery, Ischemic Time Window, and Severity of Injury Uptake of Drug-Eluting Bioresorbable Vascular Scaffolds in Clinical Practice : An NCDR Registry to Practice Project Myocardial Inflammation Predicts Remodeling and Neuroinflammation After Myocardial Infarction Contemporary Diagnosis and Management of Patients With Myocardial Infarction in the Absence of Obstructive Coronary Artery Disease: A Scientific Statement From the American Heart Association High-sensitivity troponin in the evaluation of patients with suspected acute coronary syndrome: a stepped-wedge, cluster-randomised controlled trial Patient Characteristics Associated With Antianginal Medication Escalation and De-Escalation Following Chronic Total Occlusion Percutaneous Coronary Intervention: Insights From the OPEN CTO Registry Impact of Oxidative Stress on the Heart and Vasculature: Part 2 of a 3-Part Series 2014 AHA/ACC Guideline for the Management of Patients with Non-ST-Elevation Acute Coronary Syndromes: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines

Clinical Trial2020 May 14. [Epub ahead of print]

JOURNAL:Catheter Cardiovasc Interv. Article Link

Safety and efficacy of the bioabsorbable polymer everolimus-eluting stent versus durable polymer drug-eluting stents in high-risk patients undergoing PCI: TWILIGHT-SYNERGY

U Baber, R Chandiramani, R Mehran et al. Keywords: stent comparation; DES; bioabsorbable; durable polymer; high-risk patients

ABSTRACT


BACKGROUND - Data examining the safety and efficacy of the bioabsorbable polymer (BP) drugeluting stent (DES) as compared with durable polymer (DP) DES in highrisk patients undergoing percutaneous coronary intervention (PCI) remain limited.

 

METHODS - We conducted a prespecified analysis among patients enrolled in the TWILIGHT trial treated with the SYNERGY BPDES or a DPDES. Following successful PCI and 3 months of ticagrelor plus aspirin, patients were randomized to aspirin or placebo for 1 year; DES choice was at physician discretion. The primary endpoint was target lesion failure (TLF) [composite of cardiac death, target vessel myocardial infarction (MI), clinically driven target lesion revascularization (TLR) or definite/probable stent thrombosis (ST)].

 

RESULTS - Among enrolled participants (N = 9006), 653 were treated exclusively with the SYNERGY BPDES and 6404 with a comparator DPDES. Over 15 months, TLF rates were 6.4% and 6.1% among those receiving a SYNERGY BPDES and a DPDES, respectively (adjusted HR 0.93; 95% CI 0.64 1.35; p = 0.72). The effect of ticagrelor monotherapy on Bleeding Academic Research Consortium (BARC) type 2, 3 or 5 bleeding and the composite of allcause death, MI or stroke was uniform across DES groups (both pint >0.10).

 

CONCLUSIONS - The safety and efficacy profile of the SYNERGY BPDES is comparable to that of contemporary DPDES in highrisk patients undergoing PCI. Compared to ticagrelor plus aspirin, the effect of ticagrelor monotherapy is consistent among patients receiving SYNERGY BPDES or DPDES.

 

This article is protected by copyright. All rights reserved.