In-Hospital Costs and Costs of Complications of Chronic Total Occlusion Angioplasty Insights From the OPEN-CTO Registry Long-term outcomes of rotational atherectomy of underexpanded stents. A single center experience Double kissing crush in left main coronary bifurcation lesions: A crushing blow to the rival stenting techniques Chronic Kidney Disease and Coronary Artery Disease Left Ventricular Assist Devices: Synergistic Model Between Technology and Medicine Catheterization Laboratory Considerations During the Coronavirus (COVID-19) Pandemic: From the ACC’s Interventional Council and SCAI Diagnostic performance of stress perfusion cardiac magnetic resonance for the detection of coronary artery disease: A systematic review and meta-analysis Drug-eluting balloons in coronary interventions: the quiet revolution? Classification of Deaths in Cardiovascular Outcomes Trials Known Unknowns and Unknown Unknowns Ejection Fraction Pros and Cons: JACC State-of-the-Art Review

Clinical Trial2020 May 14. [Epub ahead of print]

JOURNAL:Catheter Cardiovasc Interv. Article Link

Safety and efficacy of the bioabsorbable polymer everolimus-eluting stent versus durable polymer drug-eluting stents in high-risk patients undergoing PCI: TWILIGHT-SYNERGY

U Baber, R Chandiramani, R Mehran et al. Keywords: stent comparation; DES; bioabsorbable; durable polymer; high-risk patients

ABSTRACT


BACKGROUND - Data examining the safety and efficacy of the bioabsorbable polymer (BP) drugeluting stent (DES) as compared with durable polymer (DP) DES in highrisk patients undergoing percutaneous coronary intervention (PCI) remain limited.

 

METHODS - We conducted a prespecified analysis among patients enrolled in the TWILIGHT trial treated with the SYNERGY BPDES or a DPDES. Following successful PCI and 3 months of ticagrelor plus aspirin, patients were randomized to aspirin or placebo for 1 year; DES choice was at physician discretion. The primary endpoint was target lesion failure (TLF) [composite of cardiac death, target vessel myocardial infarction (MI), clinically driven target lesion revascularization (TLR) or definite/probable stent thrombosis (ST)].

 

RESULTS - Among enrolled participants (N = 9006), 653 were treated exclusively with the SYNERGY BPDES and 6404 with a comparator DPDES. Over 15 months, TLF rates were 6.4% and 6.1% among those receiving a SYNERGY BPDES and a DPDES, respectively (adjusted HR 0.93; 95% CI 0.64 1.35; p = 0.72). The effect of ticagrelor monotherapy on Bleeding Academic Research Consortium (BARC) type 2, 3 or 5 bleeding and the composite of allcause death, MI or stroke was uniform across DES groups (both pint >0.10).

 

CONCLUSIONS - The safety and efficacy profile of the SYNERGY BPDES is comparable to that of contemporary DPDES in highrisk patients undergoing PCI. Compared to ticagrelor plus aspirin, the effect of ticagrelor monotherapy is consistent among patients receiving SYNERGY BPDES or DPDES.

 