Risk of Mortality Following Catheter Ablation of Atrial Fibrillation The year in cardiology: heart failure: The year in cardiology 2019 Heart Failure With Mid-Range (Borderline) Ejection Fraction: Clinical Implications and Future Directions Ambulatory Inotrope Infusions in Advanced Heart Failure - A Systematic Review and Meta-Analysis How to diagnose heart failure with preserved ejection fraction: the HFA–PEFF diagnostic algorithm: a consensus recommendation from the Heart Failure Association (HFA) of the European Society of Cardiology (ESC) Impact of the Use of Intravascular Imaging on Patients Who Underwent Orbital Atherectomy Safety of the Deferral of Coronary Revascularization on the Basis of Instantaneous Wave-Free Ratio and Fractional Flow Reserve Measurements in Stable Coronary Artery Disease and Acute Coronary Syndromes Effect of Ticagrelor Monotherapy vs Ticagrelor With Aspirin on Major Bleeding and Cardiovascular Events in Patients With Acute Coronary Syndrome: The TICO Randomized Clinical Trial Imaging- and physiology-guided percutaneous coronary intervention without contrast administration in advanced renal failure: a feasibility, safety, and outcome study Initial Invasive or Conservative Strategy for Stable Coronary Disease

Clinical Trial2020 May 14. [Epub ahead of print]

JOURNAL:Catheter Cardiovasc Interv. Article Link

Safety and efficacy of the bioabsorbable polymer everolimus-eluting stent versus durable polymer drug-eluting stents in high-risk patients undergoing PCI: TWILIGHT-SYNERGY

U Baber, R Chandiramani, R Mehran et al. Keywords: stent comparation; DES; bioabsorbable; durable polymer; high-risk patients

ABSTRACT


BACKGROUND - Data examining the safety and efficacy of the bioabsorbable polymer (BP) drugeluting stent (DES) as compared with durable polymer (DP) DES in highrisk patients undergoing percutaneous coronary intervention (PCI) remain limited.

 

METHODS - We conducted a prespecified analysis among patients enrolled in the TWILIGHT trial treated with the SYNERGY BPDES or a DPDES. Following successful PCI and 3 months of ticagrelor plus aspirin, patients were randomized to aspirin or placebo for 1 year; DES choice was at physician discretion. The primary endpoint was target lesion failure (TLF) [composite of cardiac death, target vessel myocardial infarction (MI), clinically driven target lesion revascularization (TLR) or definite/probable stent thrombosis (ST)].

 

RESULTS - Among enrolled participants (N = 9006), 653 were treated exclusively with the SYNERGY BPDES and 6404 with a comparator DPDES. Over 15 months, TLF rates were 6.4% and 6.1% among those receiving a SYNERGY BPDES and a DPDES, respectively (adjusted HR 0.93; 95% CI 0.64 1.35; p = 0.72). The effect of ticagrelor monotherapy on Bleeding Academic Research Consortium (BARC) type 2, 3 or 5 bleeding and the composite of allcause death, MI or stroke was uniform across DES groups (both pint >0.10).

 

CONCLUSIONS - The safety and efficacy profile of the SYNERGY BPDES is comparable to that of contemporary DPDES in highrisk patients undergoing PCI. Compared to ticagrelor plus aspirin, the effect of ticagrelor monotherapy is consistent among patients receiving SYNERGY BPDES or DPDES.

 