CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

The Future of Biomarker-Guided Therapy for Heart Failure After the Guiding Evidence-Based Therapy Using Biomarker Intensified Treatment in Heart Failure (GUIDE-IT) Study Heart Failure With Preserved Ejection Fraction in the Young Treatment strategies for coronary in-stent restenosis: systematic review and hierarchical Bayesian network meta-analysis of 24 randomised trials and 4880 patients In vivo intravascular ultrasound-derived thin-cap fibroatheroma detection using ultrasound radiofrequency data analysis Economic and Quality-of-Life Outcomes of Natriuretic Peptide–Guided Therapy for Heart Failure Left Main Revascularization With PCI or CABG in Patients With Chronic Kidney Disease: EXCEL Trial Non-obstructive High-Risk Plaques Increase the Risk of Future Culprit Lesions Comparable to Obstructive Plaques Without High-Risk Features: The ICONIC Study Patient Selection and Clinical Outcomes in the STOPDAPT-2 Trial: An All-Comer Single-Center Registry During the Enrollment Period of the STOPDAPT-2 Randomized Controlled Trial Use of Intravascular Ultrasound Imaging in Percutaneous Coronary Intervention to Treat Left Main Coronary Artery Disease Mechanical complications of everolimus-eluting stents associated with adverse events: an intravascular ultrasound study

Original Research10 June 2020

JOURNAL:Catheter Cardiovasc Interv. Article Link

Prognostic implications of baseline 6‐min walk test performance in intermediate risk patients undergoing transcatheter aortic valve replacement

J Sathananthan, P Green, M Finn et al. Keywords: -min walk test; aortic stenosis; TAVR

ABSTRACT

BACKGROUND - While slow gait speed is known to be associated with poor outcomes in patients at high surgical risk who undergo transcatheter aortic valve replacement (TAVR), the prognostic significance of slow gait speed in intermediate risk TAVR patients is poorly understood.

 

OBJECTIVES - We assessed the association between baseline 6min walk test (6MWT) performance and both 2year mortality and health status in intermediate risk patients undergoing TAVR as a part of the PARTNER II/S3i studies.

 

METHODS - The association of baseline 6MWT with mortality over 2years after TAVR was examined using Cox regression; both unadjusted and adjusted for age, left ventricular ejection fraction, coronary artery disease, pulmonary disease, renal insufficiency, and STS score. Patients were divided into four groups according to baseline 6MWT: unable to walk and in three equal tertiles of slow, medium, and fast walkers. Among surviving patients, improvement in 6MWT and quality of life were compared.

 

RESULTS - Among 2,037 intermediate risk TAVR patients (mean age 81.7 years, STS score 5.6%), 8.2% were unable to walk. Baseline 6MWT was associated with allcause mortality over 2 years (Hazard ratio (HR) 0.87 per 50 m, 95% confidence interval [CI] 0.83 to 0.92, p < .0001). Among surviving patients, the adjusted absolute change in 6MWT at 2 years improved for patients unable to walk (+134.1 m, 95% CI 102.1 to 166 m, p < .0001) and slow walkers (+60.5 m, 95% CI 42.8 to 78.2 m, p < .0001), but was unchanged for medium walkers (7.3 m, 95% CI 24.3 to 9.6 m, p = .4), and declined for fast walkers (41.3 m, 95% CI 58.7 to 23.9 m, p < .0001).

 

CONCLUSION - Poor functional capacity is predictive of 2year mortality in elderly intermediate risk patients undergoing TAVR. However, surviving patients with poor baseline functional capacity had significant improvement in 6MWT performance and quality of life at 2years following TAVR.