CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Primary Prevention of Heart Failure in Women Design and rationale for a randomised comparison of everolimus-eluting stents and coronary artery bypass graft surgery in selected patients with left main coronary artery disease: the EXCEL trial Atherosclerotic plaque with ultrasonic attenuation affects coronary reflow and infarct size in patients with acute coronary syndrome: an intravascular ultrasound study Short- versus long-term duration of dual-antiplatelet therapy after coronary stenting: a randomized multicenter trial Six Versus 12 Months of Dual Antiplatelet Therapy After Implantation of Biodegradable Polymer Sirolimus-Eluting Stent: Randomized Substudy of the I-LOVE-IT 2 Trial Catastrophic catheter-induced coronary artery vasospasm successfully rescued using intravascular ultrasound imaging guidance Association of Abnormal Left Ventricular Functional Reserve With Outcome in Heart Failure With Preserved Ejection Fraction Optical coherence tomography and intravascular ultrasound assessment of the anatomic size and wall thickness of a muscle bridge segment Effect of Intravascular Ultrasound-Guided vs Angiography-Guided Everolimus-Eluting Stent Implantation: The IVUS-XPL Randomized Clinical Trial Twelve or 30 months of dual antiplatelet therapy after drug-eluting stents

Original Research10 June 2020

JOURNAL:Catheter Cardiovasc Interv. Article Link

Prognostic implications of baseline 6‐min walk test performance in intermediate risk patients undergoing transcatheter aortic valve replacement

J Sathananthan, P Green, M Finn et al. Keywords: -min walk test; aortic stenosis; TAVR

ABSTRACT

BACKGROUND - While slow gait speed is known to be associated with poor outcomes in patients at high surgical risk who undergo transcatheter aortic valve replacement (TAVR), the prognostic significance of slow gait speed in intermediate risk TAVR patients is poorly understood.

 

OBJECTIVES - We assessed the association between baseline 6min walk test (6MWT) performance and both 2year mortality and health status in intermediate risk patients undergoing TAVR as a part of the PARTNER II/S3i studies.

 

METHODS - The association of baseline 6MWT with mortality over 2years after TAVR was examined using Cox regression; both unadjusted and adjusted for age, left ventricular ejection fraction, coronary artery disease, pulmonary disease, renal insufficiency, and STS score. Patients were divided into four groups according to baseline 6MWT: unable to walk and in three equal tertiles of slow, medium, and fast walkers. Among surviving patients, improvement in 6MWT and quality of life were compared.

 

RESULTS - Among 2,037 intermediate risk TAVR patients (mean age 81.7 years, STS score 5.6%), 8.2% were unable to walk. Baseline 6MWT was associated with allcause mortality over 2 years (Hazard ratio (HR) 0.87 per 50 m, 95% confidence interval [CI] 0.83 to 0.92, p < .0001). Among surviving patients, the adjusted absolute change in 6MWT at 2 years improved for patients unable to walk (+134.1 m, 95% CI 102.1 to 166 m, p < .0001) and slow walkers (+60.5 m, 95% CI 42.8 to 78.2 m, p < .0001), but was unchanged for medium walkers (7.3 m, 95% CI 24.3 to 9.6 m, p = .4), and declined for fast walkers (41.3 m, 95% CI 58.7 to 23.9 m, p < .0001).

 

CONCLUSION - Poor functional capacity is predictive of 2year mortality in elderly intermediate risk patients undergoing TAVR. However, surviving patients with poor baseline functional capacity had significant improvement in 6MWT performance and quality of life at 2years following TAVR.