CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

2019 ACC/AHA/ASE Advanced Training Statement on Echocardiography (Revision of the 2003 ACC/AHA Clinical Competence Statement on Echocardiography): A Report of the ACC Competency Management Committee Regional Heterogeneity in the Coronary Vascular Response in Women With Chest Pain and Nonobstructive Coronary Artery Disease Safety and efficacy of a self-expanding versus a balloon-expandable bioprosthesis for transcatheter aortic valve replacement in patients with symptomatic severe aortic stenosis: a randomised non-inferiority trial Transcatheter Aortic Valve Replacement in Low-risk Patients With Bicuspid Aortic Valve Stenosis Dual Antiplatelet Therapy Duration: Reconciling the Inconsistencies Effects of Intravascular Ultrasound-Guided Versus Angiography-Guided New-Generation Drug-Eluting Stent Implantation: Meta-Analysis With Individual Patient-Level Data From 2,345 Randomized Patients Haemodynamic-guided management of heart failure (GUIDE-HF): a randomised controlled trial A trial to evaluate the effect of the sodium-glucose co-transporter 2 inhibitor dapagliflozin on morbidity and mortality in patients with heart failure and reduced left ventricular ejection fraction (DAPA-HF) Aspirin with or without Clopidogrel after Transcatheter Aortic-Valve Implantation Bridging the Gap Between Epigenetic and Genetic in PAH

Original Research10 June 2020

JOURNAL:Catheter Cardiovasc Interv. Article Link

Prognostic implications of baseline 6‐min walk test performance in intermediate risk patients undergoing transcatheter aortic valve replacement

J Sathananthan, P Green, M Finn et al. Keywords: -min walk test; aortic stenosis; TAVR

ABSTRACT

BACKGROUND - While slow gait speed is known to be associated with poor outcomes in patients at high surgical risk who undergo transcatheter aortic valve replacement (TAVR), the prognostic significance of slow gait speed in intermediate risk TAVR patients is poorly understood.

 

OBJECTIVES - We assessed the association between baseline 6min walk test (6MWT) performance and both 2year mortality and health status in intermediate risk patients undergoing TAVR as a part of the PARTNER II/S3i studies.

 

METHODS - The association of baseline 6MWT with mortality over 2years after TAVR was examined using Cox regression; both unadjusted and adjusted for age, left ventricular ejection fraction, coronary artery disease, pulmonary disease, renal insufficiency, and STS score. Patients were divided into four groups according to baseline 6MWT: unable to walk and in three equal tertiles of slow, medium, and fast walkers. Among surviving patients, improvement in 6MWT and quality of life were compared.

 

RESULTS - Among 2,037 intermediate risk TAVR patients (mean age 81.7 years, STS score 5.6%), 8.2% were unable to walk. Baseline 6MWT was associated with allcause mortality over 2 years (Hazard ratio (HR) 0.87 per 50 m, 95% confidence interval [CI] 0.83 to 0.92, p < .0001). Among surviving patients, the adjusted absolute change in 6MWT at 2 years improved for patients unable to walk (+134.1 m, 95% CI 102.1 to 166 m, p < .0001) and slow walkers (+60.5 m, 95% CI 42.8 to 78.2 m, p < .0001), but was unchanged for medium walkers (7.3 m, 95% CI 24.3 to 9.6 m, p = .4), and declined for fast walkers (41.3 m, 95% CI 58.7 to 23.9 m, p < .0001).

 

CONCLUSION - Poor functional capacity is predictive of 2year mortality in elderly intermediate risk patients undergoing TAVR. However, surviving patients with poor baseline functional capacity had significant improvement in 6MWT performance and quality of life at 2years following TAVR.