CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Angiographic quantitative flow ratio-guided coronary intervention (FAVOR III China): a multicentre, randomised, sham-controlled trial Randomized study on simple versus complex stenting of coronary artery bifurcation lesions: the Nordic bifurcation study Optical Coherence Tomography Predictors for Recurrent Restenosis After Paclitaxel-Coated Balloon Angioplasty for Drug-Eluting Stent Restenosis The European bifurcation club Left Main Coronary Stent study: a randomized comparison of stepwise provisional vs. systematic dual stenting strategies (EBC MAIN) Comparison of the safety and efficacy of two types of drug-eluting balloons (RESTORE DEB and SeQuent® Please) in the treatment of coronary in-stent restenosis: study protocol for a randomized controlled trial (RESTORE ISR China) In-Hospital Outcomes of Chronic Total Occlusion Percutaneous Coronary Interventions in Patients With Prior Coronary Artery Bypass Graft Surgery Multicentre, randomized comparison of two-stent and provisional stenting techniques in patients with complex coronary bifurcation lesions: the DEFINITION II trial Comparison of new-generation drug-eluting stents versus drug-coated balloon for in-stent restenosis: a meta-analysis of randomised controlled trials Sustainable Antirestenosis Effect With a Low-Dose Drug-Coated Balloon: The ILLUMENATE European Randomized Clinical Trial 2-Year Results Effect of orbital atherectomy in calcified coronary artery lesions as assessed by optical coherence tomography

Original ResearchVolume 13, Issue 12, June 2020

JOURNAL:JACC: Cardiovascular Interventions Article Link

Coronary Calcification and Long-Term Outcomes According to Drug-Eluting Stent Generation

P Guedeney, BE Claessen, GW Stone et al. Keywords: 2nd generation DES vs. 1st generation DES; moderate or severe calcification lesions; 5-year outcome

ABSTRACT

OBJECTIVES - The aim of this study was to evaluate the long-term impact of coronary artery calcification (CAC) on outcomes after percutaneous coronary intervention and the respective performance of first- and second-generation drug-eluting stents (DES).


BACKGROUND - Whether contemporary DES have improved the long-term prognosis after percutaneous coronary intervention in lesions with severe CAC is unknown.


METHODS - Individual patient data were pooled from 18 randomized trials evaluating DES, categorized according to the presence of angiography core laboratory–confirmed moderate or severe CAC. Major endpoints were the patient-oriented composite endpoint (death, myocardial infarction [MI], or any revascularization) and the device-oriented composite endpoint of target lesion failure (cardiac death, target vessel MI, or ischemia-driven target lesion revascularization). Multivariate Cox proportional regression with study as a random effect was used to assess 5-year outcomes.


RESULTS - A total of 19,833 patients were included. Moderate or severe CAC was present in 1 or more target lesions in 6,211 patients (31.3%) and was associated with increased 5-year risk for the patient-oriented composite endpoint (adjusted hazard ratio [adjHR]: 1.12; 95% confidence interval [CI]: 1.05 to 1.20) and target lesion failure (adjHR: 1.21; 95% CI: 1.09 to 1.34), as well as death, MI, and ischemia-driven target lesion revascularization. In patients with CAC, use of second-generation DES compared with first-generation DES was associated with reductions in the 5-year risk for the patient-oriented composite endpoint (adjHR: 0.88; 95% CI: 0.78 to 1.00) and target lesion failure (adjHR: 0.73; 95% CI: 0.61 to 0.87), as well as death or MI, ischemia-driven target lesion revascularization, and stent thrombosis. The relative treatment effects of second-generation compared with first-generation DES were consistent in patients with and without moderate or severe CAC, although outcomes were consistently better with contemporary devices.


CONCLUSIONS - In this large-scale study, percutaneous coronary intervention of target lesion moderate or severe CAC was associated with adverse patient-oriented and device-oriented adverse outcomes at 5 years. These detrimental effects were mitigated with second-generation DES.