CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

MITRA-FR vs. COAPT: Lessons from two trials with diametrically opposed results Ablation Versus Drug Therapy for Atrial Fibrillation in Heart Failure Results From the CABANA Trial Does pulsed field ablation regress over time? A quantitative temporal analysis of pulmonary vein isolation Percutaneous Left Atrial Appendage Occlusion for Patients in Atrial Fibrillation Suboptimal for Warfarin Therapy: 5-year Results of the PLAATO (Percutaneous Left Atrial Appendage Transcatheter Occlusion) Study The management of secondary mitral regurgitation in patients with heart failure: a joint position statement from the Heart Failure Association (HFA), European Association of Cardiovascular Imaging (EACVI), European Heart Rhythm Association (EHRA), and European Association of Percutaneous Cardiovascular Interventions (EAPCI) of the ESC Current Status and Future Prospects of Transcatheter Mitral Valve Replacement: JACC State-of-the-Art Review Prospective Evaluation of Transseptal TMVR for Failed Surgical Bioprostheses: MITRAL Trial Valve-in-Valve Arm 1-Year Outcomes 2015 ACC/HRS/SCAI Left Atrial Appendage Occlusion Device Societal Overview Systematic Review and Network Meta‐Analysis Comparing Bifurcation Techniques for Percutaneous Coronary Intervention Single direct oral anticoagulant therapy in stable patients with atrial fibrillation beyond 1 year after coronary stent implantation

Original ResearchVolume 13, Issue 12, June 2020

JOURNAL:JACC: Cardiovascular Interventions Article Link

Coronary Calcification and Long-Term Outcomes According to Drug-Eluting Stent Generation

P Guedeney, BE Claessen, GW Stone et al. Keywords: 2nd generation DES vs. 1st generation DES; moderate or severe calcification lesions; 5-year outcome

ABSTRACT

OBJECTIVES - The aim of this study was to evaluate the long-term impact of coronary artery calcification (CAC) on outcomes after percutaneous coronary intervention and the respective performance of first- and second-generation drug-eluting stents (DES).


BACKGROUND - Whether contemporary DES have improved the long-term prognosis after percutaneous coronary intervention in lesions with severe CAC is unknown.


METHODS - Individual patient data were pooled from 18 randomized trials evaluating DES, categorized according to the presence of angiography core laboratory–confirmed moderate or severe CAC. Major endpoints were the patient-oriented composite endpoint (death, myocardial infarction [MI], or any revascularization) and the device-oriented composite endpoint of target lesion failure (cardiac death, target vessel MI, or ischemia-driven target lesion revascularization). Multivariate Cox proportional regression with study as a random effect was used to assess 5-year outcomes.


RESULTS - A total of 19,833 patients were included. Moderate or severe CAC was present in 1 or more target lesions in 6,211 patients (31.3%) and was associated with increased 5-year risk for the patient-oriented composite endpoint (adjusted hazard ratio [adjHR]: 1.12; 95% confidence interval [CI]: 1.05 to 1.20) and target lesion failure (adjHR: 1.21; 95% CI: 1.09 to 1.34), as well as death, MI, and ischemia-driven target lesion revascularization. In patients with CAC, use of second-generation DES compared with first-generation DES was associated with reductions in the 5-year risk for the patient-oriented composite endpoint (adjHR: 0.88; 95% CI: 0.78 to 1.00) and target lesion failure (adjHR: 0.73; 95% CI: 0.61 to 0.87), as well as death or MI, ischemia-driven target lesion revascularization, and stent thrombosis. The relative treatment effects of second-generation compared with first-generation DES were consistent in patients with and without moderate or severe CAC, although outcomes were consistently better with contemporary devices.


CONCLUSIONS - In this large-scale study, percutaneous coronary intervention of target lesion moderate or severe CAC was associated with adverse patient-oriented and device-oriented adverse outcomes at 5 years. These detrimental effects were mitigated with second-generation DES.