CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Percutaneous coronary interventional strategies for treatment of in-stent restenosis: a network meta-analysis Randomized study on simple versus complex stenting of coronary artery bifurcation lesions: the Nordic bifurcation study Optical Coherence Tomography Predictors for Recurrent Restenosis After Paclitaxel-Coated Balloon Angioplasty for Drug-Eluting Stent Restenosis The European bifurcation club Left Main Coronary Stent study: a randomized comparison of stepwise provisional vs. systematic dual stenting strategies (EBC MAIN) Comparison of the safety and efficacy of two types of drug-eluting balloons (RESTORE DEB and SeQuent® Please) in the treatment of coronary in-stent restenosis: study protocol for a randomized controlled trial (RESTORE ISR China) In-Hospital Outcomes of Chronic Total Occlusion Percutaneous Coronary Interventions in Patients With Prior Coronary Artery Bypass Graft Surgery Effect of orbital atherectomy in calcified coronary artery lesions as assessed by optical coherence tomography Comparison of new-generation drug-eluting stents versus drug-coated balloon for in-stent restenosis: a meta-analysis of randomised controlled trials Multicentre, randomized comparison of two-stent and provisional stenting techniques in patients with complex coronary bifurcation lesions: the DEFINITION II trial Sustainable Antirestenosis Effect With a Low-Dose Drug-Coated Balloon: The ILLUMENATE European Randomized Clinical Trial 2-Year Results

Original ResearchVolume 13, Issue 12, June 2020

JOURNAL:JACC: Cardiovascular Interventions Article Link

Coronary Calcification and Long-Term Outcomes According to Drug-Eluting Stent Generation

P Guedeney, BE Claessen, GW Stone et al. Keywords: 2nd generation DES vs. 1st generation DES; moderate or severe calcification lesions; 5-year outcome

ABSTRACT

OBJECTIVES - The aim of this study was to evaluate the long-term impact of coronary artery calcification (CAC) on outcomes after percutaneous coronary intervention and the respective performance of first- and second-generation drug-eluting stents (DES).


BACKGROUND - Whether contemporary DES have improved the long-term prognosis after percutaneous coronary intervention in lesions with severe CAC is unknown.


METHODS - Individual patient data were pooled from 18 randomized trials evaluating DES, categorized according to the presence of angiography core laboratory–confirmed moderate or severe CAC. Major endpoints were the patient-oriented composite endpoint (death, myocardial infarction [MI], or any revascularization) and the device-oriented composite endpoint of target lesion failure (cardiac death, target vessel MI, or ischemia-driven target lesion revascularization). Multivariate Cox proportional regression with study as a random effect was used to assess 5-year outcomes.


RESULTS - A total of 19,833 patients were included. Moderate or severe CAC was present in 1 or more target lesions in 6,211 patients (31.3%) and was associated with increased 5-year risk for the patient-oriented composite endpoint (adjusted hazard ratio [adjHR]: 1.12; 95% confidence interval [CI]: 1.05 to 1.20) and target lesion failure (adjHR: 1.21; 95% CI: 1.09 to 1.34), as well as death, MI, and ischemia-driven target lesion revascularization. In patients with CAC, use of second-generation DES compared with first-generation DES was associated with reductions in the 5-year risk for the patient-oriented composite endpoint (adjHR: 0.88; 95% CI: 0.78 to 1.00) and target lesion failure (adjHR: 0.73; 95% CI: 0.61 to 0.87), as well as death or MI, ischemia-driven target lesion revascularization, and stent thrombosis. The relative treatment effects of second-generation compared with first-generation DES were consistent in patients with and without moderate or severe CAC, although outcomes were consistently better with contemporary devices.


CONCLUSIONS - In this large-scale study, percutaneous coronary intervention of target lesion moderate or severe CAC was associated with adverse patient-oriented and device-oriented adverse outcomes at 5 years. These detrimental effects were mitigated with second-generation DES.