CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Combining IVUS and Optical Coherence Tomography for More Accurate Coronary Cap Thickness Quantification and Stress/Strain Calculations: A Patient-Specific Three-Dimensional Fluid-Structure Interaction Modeling Approach De-escalation of antianginal medications after successful chronic total occlusion percutaneous coronary intervention: Frequency and relationship with health status The HACD4 haplotype as a risk factor for atherosclerosis in males Changes in One-Year Mortality in Elderly Patients Admitted with Acute Myocardial Infarction in Relation with Early Management The Impact of Proximal Vessel Tortuosity on the Outcomes of Chronic Total Occlusion Percutaneous Coronary Intervention: Insights From a Contemporary Multicenter Registry Prospective Elimination of Distal Coronary Sinus to Left Atrial Connection for Atrial Fibrillation Ablation (PRECAF) Randomized Controlled Trial Eruptive Calcified Nodules as a Potential Mechanism of Acute Coronary Thrombosis and Sudden Death Long-term Survival following Multivessel Revascularization in Patients with Diabetes (FREEDOM Follow-On Study) Stent fracture is associated with a higher mortality in patients with type-2 diabetes treated by implantation of a second-generation drug-eluting stent Comparison of Stent Expansion Guided by Optical Coherence Tomography Versus Intravascular Ultrasound: The ILUMIEN II Study (Observational Study of Optical Coherence Tomography [OCT] in Patients Undergoing Fractional Flow Reserve [FFR] and Percutaneous Coronary Intervention)

Original ResearchVolume 13, Issue 12, June 2020

JOURNAL:JACC: Cardiovascular Interventions Article Link

Coronary Calcification and Long-Term Outcomes According to Drug-Eluting Stent Generation

P Guedeney, BE Claessen, GW Stone et al. Keywords: 2nd generation DES vs. 1st generation DES; moderate or severe calcification lesions; 5-year outcome

ABSTRACT

OBJECTIVES - The aim of this study was to evaluate the long-term impact of coronary artery calcification (CAC) on outcomes after percutaneous coronary intervention and the respective performance of first- and second-generation drug-eluting stents (DES).


BACKGROUND - Whether contemporary DES have improved the long-term prognosis after percutaneous coronary intervention in lesions with severe CAC is unknown.


METHODS - Individual patient data were pooled from 18 randomized trials evaluating DES, categorized according to the presence of angiography core laboratory–confirmed moderate or severe CAC. Major endpoints were the patient-oriented composite endpoint (death, myocardial infarction [MI], or any revascularization) and the device-oriented composite endpoint of target lesion failure (cardiac death, target vessel MI, or ischemia-driven target lesion revascularization). Multivariate Cox proportional regression with study as a random effect was used to assess 5-year outcomes.


RESULTS - A total of 19,833 patients were included. Moderate or severe CAC was present in 1 or more target lesions in 6,211 patients (31.3%) and was associated with increased 5-year risk for the patient-oriented composite endpoint (adjusted hazard ratio [adjHR]: 1.12; 95% confidence interval [CI]: 1.05 to 1.20) and target lesion failure (adjHR: 1.21; 95% CI: 1.09 to 1.34), as well as death, MI, and ischemia-driven target lesion revascularization. In patients with CAC, use of second-generation DES compared with first-generation DES was associated with reductions in the 5-year risk for the patient-oriented composite endpoint (adjHR: 0.88; 95% CI: 0.78 to 1.00) and target lesion failure (adjHR: 0.73; 95% CI: 0.61 to 0.87), as well as death or MI, ischemia-driven target lesion revascularization, and stent thrombosis. The relative treatment effects of second-generation compared with first-generation DES were consistent in patients with and without moderate or severe CAC, although outcomes were consistently better with contemporary devices.


CONCLUSIONS - In this large-scale study, percutaneous coronary intervention of target lesion moderate or severe CAC was associated with adverse patient-oriented and device-oriented adverse outcomes at 5 years. These detrimental effects were mitigated with second-generation DES.